The Remote Interlock Bypass may be replaced by the
user’s own interlock system using a switch or dry relay
closure to connect pins 1 and 2. With pins 1 and 2 shorted,
Laser Emission is possible, provided all other interlocks are
closed circuit. With pins 1 and 2 open, NO Laser Emission
is possible.
The projector’s REMOTE Output is used to daisy-chain the
Remote signal when you want to use a single Emergency
STOP Remote to control multiple systems.
After a power failure or interlock failure (open circuit)
has occurred and been corrected you need to manually
reset laser emission by pressing the START button on the
E-STOP Remote.
5. Ethernet.
Use these ports to connect PC control signal or to daisy
chain the control signal between multiple laser display
systems.
6. 12 Locking holes with bolts.
Use them to join individuals units together.
7. Safety eyelet.
Use this together with appropriate safety wire to secure
the system against unexpected fall.