5.3
rear vIew
1. Mains power INPUT/OUTPUT.
Use supplied Neutrik powerCON TRUE1 power cable
to connect the laser system to mains power supply using
the INPUT connector. The OUTPUT connector is used
to daisy chain power between multiple laser systems for
quick and easy installation.
2. Power ON indicator.
The powerCON TRUE1 is a connector with breaking
capacity (CBC), i.e. it can be connected or disconnected
under load or live.
3.Safety key switch.
The Safety key must be inserted and turned to ON position
in order to enable the system to operate.
4. E-STOP Remote connector, Interlock status indicator
and User Interlock.
In order to use the laser system, the Interlock must
be closed circuit. This is done by connecting the Emergency
STOP Remote to the XLR REMOTE INPUT socket on the
projector using the supplied cable. The US version of the
Emergency STOP must also have the Remote Interlock
Bypass inserted into it.
!
The E-STOP Remote is an integral
part of the laser projector. It is there
for the safety of the public as well
as the operator. In most countries
it is required by law to have a fully
working Emergency STOP in place for
every laser system used. Modifying
or using anything other than the E-STOP
Remote provided, in the manner it was
intended, may invalidate your laser
projector’s variance.