1. Mains power INPUT/OUTPUT.
Use supplied Neutrik
powerCON TRUE1 power cable to connect the laser system
to mains power supply using the INPUT connector. The
OUTPUT connector is used to daisy chain power between
multiple laser systems for quick and easy installation.
The
powerCON TRUE1
is a connector with breaking capacity
(CBC), i.e. it can be connected or disconnected under load
or live.
2. E-STOP Remote connector, Interlock status indicator
and User Interlock.
In order to use the laser system, the
Interlock must be closed circuit. This is done by connecting
the Emergency STOP Remote to the XLR REMOTE INPUT
socket on the projector using the supplied cable. The
US version of the Emergency STOP must also have the
Remote Interlock Bypass inserted into it .
!
The E-STOP Remote is an integral
part of the laser projector. It is there
for the safety of the public as well
as the operator. In most countries
it is required by law to have a fully
working Emergency STOP in place for
every laser system used. Modifying
or using anything other than the E-STOP
Remote provided, in the manner it was
intended, may invalidate your laser
projector’s variance.
The Remote Interlock Bypass may be replaced by the
user’s own interlock system using a switch or dry relay
closure to connect pins 1 and 2. With pins 1 and 2 shorted,
Laser Emission is possible, provided all other interlocks are
closed circuit. With pins 1 and 2 open, NO Laser Emission
is possible.
The Interlock status indicator START (2) goes off and status
indicator READY (2) lights up when the Interlock is closed
circuit and the Interlock key is in the ON position. All above
must be done correctly to allow laser emission from the
system.