31
|
38
Atom series - v160120
Kvant Lasers s.r.o.
EN
4. Power up the system as normal.
5. Create a red beam effect (point) and check visually whether the red beam hits the exact centre of the bottom scanning
mirror. If not, use dichroic mounts DF5 to adjust the beam path accordingly (diagram below). To adjust the dichroic
mount use the two adjustment knobs – each works for one axis.
6. Create a cyan beam effect (point) and check visually whether the green beam hits the exact centre of the blue beam
at the dichroic filter DF2. If not, use dichroic mounts DF1 to adjust the beam path accordingly. To adjust the dichroic
mount use the two adjustment knobs – each works for one axis.
7. Create a full size cyan circle (static tunnel effect) and check whether the green circle overlays the blue circle in all
points around the shape. If not, use dichroic mount DF2 to adjust the beam path accordingly. To adjust the dichroic
mount use the two adjustment knobs – each works for one axis.
8. Create a full size yellow circle (static tunnel effect) and check whether the green circle overlays the red circle in all
points around the shape. If not, use dichroic mount DF3 and/or DF4 to adjust the beam path accordingly. To adjust
the dichroic mount use the two adjustment knobs – each works for one axis.
9. Finally create a full size white circle (static tunnel effect). If the alignment procedure was done successfully you can
see all the colours nicely overlaying each other, resulting in even, bright and sharp circle like the one on the picture
below.