
Troubleshooting the Air Cylinders
KVAL 990-F4 Service Manual
4-24
a.The solenoid valves can be manually operated by pushing the red manual
override button on the end of the valve.
b.If the valve seems to be leaking, the seals may be dry or contaminated with
water or it maybe that the cylinder “O” rings are damaged and air is passing
from one side to the other side of the cylinder which means the air is exhaust
-
ing through the solenoid valve. It maybe is necessary to purchase a rebuild kit
or a new cylinder.
c.If the valve is not receiving an electrical signal, for instructions. It might be
necessary to call in a specialist or check with
KVAL
customer service at 1-800-
553-5825.
5.
If an Air Leak is coming from an exhaust port on the solenoid air bank:
a.Check the solenoid for the manual override. If the solenoid has a manual over
-
ride you can push each of the buttons one at a time. When the air leak stops or
weakens it usually means that one or more of the cylinders that the solenoid is
operating are faulty.
Adjusting Cylinder Extension Speed:
Adjusting Cylinder Retraction Speed:
Once activated, The valve will allow
full pressure to
cylinder.
Make sure you are clear of all moving parts.
Caution