ADVR-12

 

SECTION 1 : SPECIFICATION 

Sensing Input (20, 22, 24) 

Static Power Dissipation

 

  Voltage 

220 

 520 Vac 

  Max. 12 watts 

   

1- or 3- phase selectable 

 

   

180 

 260 Vac @ 220 Vac 

Burden in SHUNT & PMG Wiring

 

   

330 

 520 Vac @ 440 Vac 

  1320 VA @ power input 110 Vac 

  Frequency 

50/60 Hz, selectable 

  2640 VA @ power input 220 Vac 

 

 

Power Input (26, 28, 30)

 

Quadrature Droop Input (C1, C2) 

  Voltage 

60 

 300 Vac, 1 or 3 phase 

  CT 1A or 5A greater than 5VA (DIP switch setting) 

  Frequency 

40 

 500 Hz 

  Sensi/- 7% @ PF +/- 0.5 (Droop adjustable) 

 

 

Excitation Output (F1, F2)

 

Analogue Voltage Input (2, 3) 

  Voltage 

63 Vdc @ power input 110 Vac 1 Phase    Un 0 

 10% @ 0 

 10 Vdc or +/- 5 Vdc 

   

75 Vdc @ power input 110 Vac 3 Phase 

 

   

125 Vdc @ power input 220 Vac 1 Phase 

Under Frequency Protection (Factory Presets) 

   

150 Vdc @ power input 220 Vac 3 Phase 

  50 Hz system presets knee point at 45 Hz 

  Current 

Continuous 12A 

  60 Hz system presets knee point at 55 Hz 

   

Intermittent 20A for 10 secs. 

 

  Resistance 

  5 ohms @ power input 110 Vac 

Over Excitation Protection 

   

  11 ohms @ power input 220 Vac 

  Set point 125 Vdc +/- 5 % @ power input 220 Vac 

  Fuse Spec. 

Slow blow 6.3 x 32mm 12.5A / 500V 

  Inverse-time curve. This function can be turned off. 

 

 

External Voltage Adjustment

 

Voltage Thermal Drift 

  10K ohms 1 watt potentiometer 

  Less than 3% at temperature range -40 to +70 

˚C 

 

 

Voltage Regulation

 

Under-Frequency Knee Point Thermal Drift 

  Less than +/- 0.5% ( with 4% engine governing ) 

  Less than +/- 0.1 Hz at -

40 to +70 ˚C 

 

 

Build Up Voltage

 

Environment 

  6 Vac 25 Hz residual volts at power input terminal 

  Operating Temperature 

-40 to +70 

˚C 

 

  Storage Temperature 

-40 to +85 

˚C 

Soft Start Ramp Time 

  Relative Humidity 

Max. 95% 

  4 s/- 10%

 

  Vibration 

3.0 Gs @ 100 

 2K Hz 

 

 

Typical System Response 

Dimensions 

  Less than 20 milliseconds 

  214.0 (L) x 163.0 (W) x 45.7 (H) mm

 

 

 

EMI Suppression 

Weight 

  Internal electromagnetic interference filtering

 

  1130 g +/- 2%

 

 

Summary of Contents for ADVR-12

Page 1: ...Manual Self Excited Automatic Voltage Regulator For use in Brushless SHUNT PMG and Auxiliary Winding Compatible with Basler AVC63 12 AVC125 10 CATERPILLAR VR6 Kato K65 12B K125 10B Leroy Somer 202 8634 regulators Use with KUTAI IVT 1260 IVT 2460 add on module can boost generator motor starting capacity All manufacturer names and numbers are used for reference purpose only and do not imply that any...

Page 2: ...20 Vac 3 Phase 50 Hz system presets knee point at 45 Hz Current Continuous 12A 60 Hz system presets knee point at 55 Hz Intermittent 20A for 10 secs Resistance 5 ohms power input 110 Vac Over Excitation Protection 11 ohms power input 220 Vac Set point 125 Vdc 5 power input 220 Vac Fuse Spec Slow blow 6 3 x 32mm 12 5A 500V Inverse time curve This function can be turned off External Voltage Adjustme...

Page 3: ...est equipment must not be used Use of such equipment could damage the AVR 3 Secure all wiring connections Do not install AVR in a high vibration area to avoid loose connections For safety do not touch the heat sink while in operation 4 Improper setting of under frequency protection could cause the output voltage of the unit to drop or become unstable under with changes in load Avoid making any cha...

Page 4: ...ed by any bias voltage Conversely if the TRIM is adjusted fully clockwise then any signal will produce the maximum 10 effect 3 6 U F DIP Adjustment DIP When U F protection is activated the voltage droop ratio can be adjusted via the DIP VR The adjustable range is 3 10 V Hz 3 7 Over Excitation LED O E Indicator illuminates when the generator is in Over Excitation protection Set point 125 Vdc 5 220 ...

Page 5: ...Three Phase Sensing SHUNT Figure 4 Single Phase Sensing PMG or Auxiliary Winding S T R 20 GEN 22 24 26 28 30 F1 F2 CH GND 2 3 4 5 5a 6 6a 7 8 9 CT ADVR 12 FIELD F F Sensing Power PT1 PT2 S T R 20 22 24 26 28 30 F1 F2 CH GND 2 3 4 5 5a 6 6a 7 8 9 CT ADVR 12 Sensing Power PMG GEN CT FIELD F F PT1 Figure 5 Three Phase Sensing with power transformer If sensing or power voltage differs from ADVR 12 add...

Page 6: ...ohms 1 watt Adjustable range is the same VOLT range 4 Sensing Voltage can be set from 220 440 Vac Program SW5 correctly 5 For single phase sensing bridge 20 22 and open 6a 9 6 When using PT1 of capacity 100VA must pay attention that the voltage and capacity of transformer PT2 has adequate excitation output Use only replacement fuses specified in this user manual Appearance and specifications of pr...

Reviews: