background image

VEHICLE WIRING INSTALLATION

1. The Auto Pump is supplied with a 120 volt A.C. line cord and is ready to operate. The line

cord may be plugged into an available outlet or the cord may be cut and permanently wired to

the 120 volt A.C. system in the vehicle.

2. The compressor is calibrated to cut-in at 70 PSI and cut-out at 90 PSI .  For higher cut-in

and cut-out, turn the range nut clockwise .  To lower cut-in turn range nut counterclockwise .

Do not exceed 100 PSI .

COMPRESSOR OUTPUT IS 100 PSI MAXIMUM. DO

NOT EXCEED 100 PSI OR YOU WILL VOID

WARRANTY.

NOTE

NOTE

NOTE

NOTE

NOTE

THIS PUMP REQUIRES A MINAMUM OF 110

THIS PUMP REQUIRES A MINAMUM OF 110

THIS PUMP REQUIRES A MINAMUM OF 110

THIS PUMP REQUIRES A MINAMUM OF 110

THIS PUMP REQUIRES A MINAMUM OF 110

VOLTS FOR OPERATIONAT LOWER VOLTAGES

VOLTS FOR OPERATIONAT LOWER VOLTAGES

VOLTS FOR OPERATIONAT LOWER VOLTAGES

VOLTS FOR OPERATIONAT LOWER VOLTAGES

VOLTS FOR OPERATIONAT LOWER VOLTAGES

THE PUMPWILL NOT START

THE PUMPWILL NOT START

THE PUMPWILL NOT START

THE PUMPWILL NOT START

THE PUMPWILL NOT START

Summary of Contents for Auto-Pump 091-9B-1

Page 1: ... 0857 FAX 631 567 5826 1 YEAR WARRANTY BOOK 091 9B 1 Rev A 12 14 04 file 091 9b 1 reva KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 INPUT 120 volt 60 Hz 4 2 AMPS OUTPUT 100 PSI MAXIMUM AUTO PUMP 120VAC AIR COMPRESSOR SYSTEM MODEL 091 9B 1 ...

Page 2: ...sor when the system pressure drops below 70 psi and stops the compressor when 90 psi is attained The start up pressure is field adjustable the pressure differential between start up and stopping is fixed A moisture trap is mounted on the Auto Pump This captures any condensate which results from compressing the air In addition the moisture trap in combination with the check valve and the unloader o...

Page 3: ... MUST BE ALLOWED TO ENTER OR ACCUMULATE IN THE OUTPUT OF THE AUTO PUMP ROUTE OUTPUT PRESSURE LINE DOWNWARD FROM AUTO PUMP TO PERMIT MOISTURE TO DRAIN AWAY WATER IN THE PUMP OUTLET WILL INDUCE FAILURE WATER DAMAGE WILL VOID WARRANTY ...

Page 4: ... the pump outlet will induce failure 4 All connection for air lines are 1 4 NPT Use Teflon tape or equivalent on all connections to insure no leakage of air 5 The recommended installation of the Auto Pump air compressor system is shown below 6 Note that an external check valve is located beteen the compressor and the pressure switch no additional check valve is required 7 Mount the air compressor ...

Page 5: ...rclockwise Do not exceed 100 PSI COMPRESSOR OUTPUT IS 100 PSI MAXIMUM DO NOT EXCEED 100 PSI OR YOU WILL VOID WARRANTY NOTE NOTE NOTE NOTE NOTE THIS PUMP REQUIRES A MINAMUM OF 110 THIS PUMP REQUIRES A MINAMUM OF 110 THIS PUMP REQUIRES A MINAMUM OF 110 THIS PUMP REQUIRES A MINAMUM OF 110 THIS PUMP REQUIRES A MINAMUM OF 110 VOLTS FOR OPERATIONAT LOWER VOLTAGES VOLTS FOR OPERATIONAT LOWER VOLTAGES VOL...

Page 6: ... Weight 13 lbs Motor Horsepower 1 8 HP Motor Type Shaded pole A C Compressor Output 0 76 CFM Open Flow 100 PSI Maximum Pressure Switch Adjustable Set Point Factory set to 70 PSI Cut in 90 PSI Cut out Switch Differential 20 PSI Nominal Outlet Connection 1 4 NPT Female ...

Page 7: ...TEMPLATE AUTO PUMP 3 50 4 75 7 32 DIA HOLES 4PLACES ...

Page 8: ...SPARE PARTS LAYOUT AUTO PUMP ...

Page 9: ...epair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the equipment assumes all liability for any damages which may result from its installation use or misuse by the purchaser his or its employees...