background image

IMPORTANT SAFETY INSTRUCTIONS

I.  PERSONAL PRECAUTIONS

1.  Someone should be within range of your voice or close enough to come to your aid when you work near 

a lead-acid battery. 

2.  Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 

3.  Wear complete eye and clothing protection. Avoid touching your eyes while working near a battery. 

4.  If battery acid contacts skin or clothing, wash immediately with soap and water. If battery acid enters 

the eye, immediately flood eye with cold running water for at least 10 minutes and get medical attention 

immediately. 

5.  NEVER

 smoke or allow a spark or flame in the vicinity of the battery or engine. 

6.  Be extra cautious to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit 

the battery or other electrical part and cause a fire or an explosion. 

7.  Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a 

lead-acid battery. A lead-acid battery, when shorted, can produce a current sufficient to weld a ring or the 

like metal causing a severe burn. 

8. 

Use the battery charger for charging gel-cell, AGM and flooded lead-acid batteries only.  Do not use the 

charger for charging dry-cell batteries that are commonly used with home applications. These batteries 

may burst and cause injury to persons and damage to property. 

9.  WARNING – RISK OF EXPLOSIVE GASES

:  Working in the vicinity of a lead-acid battery is dangerous. 

Batteries generate explosive gases during normal battery operation. 

II.  CHARGER PRECAUTIONS

:

1.  NEVER

 charge a frozen battery.

2.  Make sure the cord is located so that it will not be stepped on, tripped over, or otherwise subjected to 

damage or stress.

3. 

Do not operate the charger with a damaged cord or plug; replace them immediately. 

4. 

Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged.

5. 

Do not disassemble the charger. Incorrect reassembly may result in a risk of electric shock and fire. 

6.  To reduce the risk of electric shock, disconnect the charger from the AC source before attempting any 

maintenance or cleaning. 

7.  LOCATION OF CHARGER

: The charger should be mounted on a wall, vehicle floor, ventilated compart

-

ment or other suitable surface as close to the batteries to be charged as possible. Do not block the char

-

ger’s fan or air intakes. Do not mount the charger directly over the batteries as fumes may cause exces

-

sive corrosion. The area should be well ventilated and free from excessive moisture, exhaust manifolds, 

and battery fumes. For maximum performance, the charger should not be located in an area of extreme 

high temperature. The charger is not waterproof. Do not mount the charger where there is a possibility of 

water entering the unit. Evidence of water entry into the charger will void the warranty.

8.  CAUTION

: Do not attempt to increase battery bank capacity by splitting the output of one of the banks 

with a diode-type battery isolator.  The diode isolator lowers the charger voltage and results in under-

charging the batteries connected to it. If additional capacity is required it is preferable to add another 

isolated or parallel battery.

III.  GROUND AND AC POWER CORD CONNECTION

:

1.  The charger should be grounded via the AC power connection to reduce the risk of electrical shock.

2.  The charger must be plugged into or wired to an outlet that is an over-current protected 3 prong outlet. 

Alternatively, it may be routed through a separate dedicated fuse or circuit breaker on an AC distribution 

panel with proper earth/safety ground.  All wiring shall comply with UL recommendations, NEC or NFPA 

standards and local ordinances.  Never alter the AC cord or plug if provided.  Any modification of the cord 

must only be done by a qualified electrician.  Improper cord/outlet connection may result in a risk of elec

-

trical shock.

3.  Observe color coding of the AC wiring as follows:   

 

  

Black……….......................  AC Hot or LINE (fused)  

  

White…………...................  AC Neutral  

  

Green…….................…….. AC Ground (safety/earth)  

4.  CAUTION

: (230 VAC applications only): If AC input is provide from a source consisting of two HOT or 

LINE leads (phase-to-phase 230 VAC input voltage); an external fuse or circuit breaker must be used to 

protect both hot leads.

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826

[email protected]

2

Summary of Contents for AUTO CHARGE DUAL 091-145-12

Page 1: ... BATTERY CHARGER scan using your mobile device for more information INSTRUCTION MANUAL INPUT 120 Volt 50 60 Hz 3 5 Amps OUTPUT BAT 1 10 Amps OUTPUT BAT 2 10 Amps 3 YEAR WARRANTY MODEL 091 145 12 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com ...

Page 2: ...ger from the AC source before attempting any maintenance or cleaning 7 LOCATION OF CHARGER The charger should be mounted on a wall vehicle floor ventilated compart ment or other suitable surface as close to the batteries to be charged as possible Do not block the char ger s fan or air intakes Do not mount the charger directly over the batteries as fumes may cause exces sive corrosion The area shou...

Page 3: ...ge Automatic electronic remote sensing measures the true battery voltage eliminating the need for the additional sense wires The output current of any charger is inherently a series of pulses whose frequency is determined by the power line frequency Therefore there are brief intervals during which no charging current flows Since there is no charging current there is also no voltage drop between th...

Page 4: ...l 4 Apply AC power shoreline power to input terminal and observe that the charger is operating 5 Verify that the battery voltage appears at the charger output terminals A minimum of 9 volts is required to start the charger II WIRING SPECIFICATIONS 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 4 Length of Wire to Battery feet Battery C...

Page 5: ...ION WIRING DIAGRAM I FOR 2 INDIVIDUAL BATTERIES Wiring Diagram shown is for a 10 foot installation 5 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com ...

Page 6: ...800 346 0857 Fax 631 567 5826 sales kussmaul com The Series connection of the two 12 volt batteries produces 24 volts Each battery is individually charged at 12volts Even though the batteries may supply different loads each battery is automaticl ly supplied with the correct charging current When each of the batteries is fully charged the charger stops charging ...

Page 7: ... 13 12 VDC Output Power 131 Watts per output 262 Total Output Ripple 0 5 Vrms Charger 0 1 Vrms Battery Efficiency 62 Line Regulation 0 4 Load Regulation 1 Storage Temp 20 to 80 C Operating Temp 0 to 40 C Isolation Hi pot 1200 VDC Weight 22 pounds Short Circuit Protected Yes Battery Required To Operate Yes Charger Technology SCR Output Current Limited Yes automatic Input Current Limited Yes fuse Fa...

Page 8: ...aterial or defects which become apparent in normal use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kuss maul Electronics Compan...