background image

THREE STAGE CHARGING CURVE

BATTERY

CURRENT

BATTERY
VOLTAGE

FLOAT

STAGE

ABSORPTION STAGE

Voltage Increasing

Current Constant

Voltage Constant

Current Decreasing

Voltage Constant

Full Charge Maintained

STAGE I

CONSTANT CURRENT

(BULK)

STAGE II

CONSTANT VOLTAGE

(ABSORPTION)

STAGE III

CONSTANT VOLTAGE

(FLOAT)

TIME

Figure 1

14.70VDC

13.60VDC

I Limit=40.0A

8.0 Hours

Model: 091-128-12E-40-115

Summary of Contents for 091-128-12E-40-115

Page 1: ...0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO CHARGE ODY AUTOMATIC BATTERY CHARGER 3 YEAR WARRANTY MODEL 091 128 12E 40 115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the ODYSSEY requirementof 14 7 volts in the bulk absorption range and 13 6 volts in the float mode DO NOT USE TO CHARGE A NORMAL FLOODED LEAD ACID BATTERY q ...

Page 2: ...ications BATTERY CHARGER FEATURES Completely automatic operation charges battery on demand Output Voltage regulated eliminates overcharging battery Output Voltage temperature compensated optional Output current limited to protect charger from overloading A 5 LED display indicating charge state and faults Reverse polarity protection INSTALLATION The AUTO CHARGEd ODY should be installed in an area w...

Page 3: ...e and the green indicator labeled Battery Charged AND red indicator labeled Time Out will be illuminated Figure 1 depicts the above described operation Note that the term absorption charge is used interchangeably with finish charge Upon application of AC power the charger is placed into bulk charge if necessary When the charger switches to finish charge a timer starts This timer has a duration of ...

Page 4: ...oltage Increasing Current Constant Voltage Constant Current Decreasing Voltage Constant Full Charge Maintained STAGE I CONSTANT CURRENT BULK STAGE II CONSTANT VOLTAGE ABSORPTION STAGE III CONSTANT VOLTAGE FLOAT TIME Figure 1 14 70VDC 13 60VDC I Limit 40 0A 8 0 Hours Model 091 128 12E 40 115 ...

Page 5: ......

Page 6: ... Output Power 12 to 14 7VDC 40Amperes Current Limited Charge Indicator 50Amperes Mode Indicators Battery Fault Red TimeOut Red Bulk Charge Yellow Finish Charge Yellow Battery Charged Green Recommended Battery Size Odyssey AGM Series PC 150 to 300 AH Weight 28 Pounds Temperature Compensation Optional not used on this model ...

Page 7: ......

Page 8: ...14 0 9 31 9 25 Figure 3 OUTLINE DRAWING ...

Page 9: ...y material or defects which become apparent in normal use within 3 years from the date the equipment was shipped Kussmaul Electronics Company Inc shall have no liability for dam ages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The pur chaser by the acceptance of the equipment assumes all liability for any damages whi...