background image

DESCRIPTION 

Our dear customer, 

Your preferred KUSİNA is nature and technology friendly. We thank you for your choice. 

KUSİNA has been produced with the understanding of "Total Quality" in modern production facilities. 

Important Safety Information 

Carefully read this guide and keep it for future review

WARNING:

 Installation of the devices must be done by an authorized service person. 

WARNING:

 Equipment must be grounded. 

 

  Indicates that there is a risk of personal injury or property damage. 

  

Explosion / fire hazard. 

 

Mounting,  electrical  connection  and  maintenance  works  of  the  device  should  be  performed  by  a 
specialist  authorized  in  this  subject  and  in  accordance  with  the  instructions  of  the  manufacturer 
company.  

 

Electrical  connection  of  the  device  should  be  arranged  according  to  the  tables  and  electrical  diagram 
given in this manual. 

 

Manufacturer Company accepts no responsibility for the final damages that are caused by any procedure 
not  conforming  to  the  instruction  manual,  or  maintenance  or  technical  interventions  that  are  not 
performed by authorized people.   

MOUNTING INSTRUCTIONS 
PLACEMENT 

 

Installation and adjustment of the device should be carried out by experienced technical staff. 

 

In order to prevent smell and fume formation, place the device beneath an exhaust hood being capable 
of enough ventilation.  

 

Place the device at a place min. 10cm away from the side or back wall to prevent excessive temperature 
rises.   

 

Device should be placed on a flat surface by suitably balancing on the four adjustable legs. (Figure A) 

 

Remove the nylon protection cover on the device. If there are any adhesive residues left on the surface, 
clean with a suitable solvent. 

 

Never leave flammable material near the device. 

 

ELECTRICAL CONNECTION 

 

Connect  the  device  to  the  electrical  installation  according  to  the  electrical  standards  of  the  relevant 
country. 

 

Feed the device with suitable network voltage written on the information plate. 

 

Connect to the electrical installation over a suitable automatic fuse. Fix the said fuse on a place that is 
easily accessible in case of a danger. 

 

The cable connecting the device to the electrical installation should be at least type H05 RNF. 

 

Before connecting the electrical inlet cable to the electrical inlet clamp, connect the cable on the device 
by passing it through the inlet coupling and then tighten the coupling cover in  a manner that does not 
allow cable return.  

 

Voltage tolerance should not exceed ± 10%. 

 

Electrical inlet clamp can be seen by disassembling front panel.  

Summary of Contents for G6F100E

Page 1: ...FRYER ELECTRICAL INSTRUCTION AND MAINTENANCE MANUAL Professionally with Professionals ...

Page 2: ... carried out by experienced technical staff In order to prevent smell and fume formation place the device beneath an exhaust hood being capable of enough ventilation Place the device at a place min 10cm away from the side or back wall to prevent excessive temperature rises Device should be placed on a flat surface by suitably balancing on the four adjustable legs Figure A Remove the nylon protecti...

Page 3: ...also burned and carbonized residue accumulation on heater and chamber surface Refill oil when it descends to minimum level Minimum and maximum oil levels are marked on oil container Figure B Do not place foods without draining their water or foods with solid ice parts Rise up the movable headed heater group 4 through its lever to allow cleaning Afterwards you should side shift support latch 5 to t...

Page 4: ...t sound is emitted If this limit switch activates the circuit again after the oil is heated apply to the authorized service Table 1 Figure A MAX MIN Şekil B Figure B Figure B MODEL G6F100E G6F200E G7F100E G7F200E G9F100E G9F200E Width A mm 400 600 400 800 400 800 Dept B mm 600 600 730 730 900 900 Hight C mm 300 300 900 900 900 900 Power KW 7 5 15 14 14 14 17 17 17 Electrical Inlet 400V 3N PE 400V ...

Page 5: ...6 7 8 Figure D G6F100E G6F200E Compatibility Information This device is designed and manufactured in accordance with the following directives and standards marking directive 93 68 EEC TS EN 60335 1 2012 AC TS EN 60335 2 37 Related to CE Directive s 2014 35 EU Low Voltage ...

Page 6: ...LEKTRİK GİRİŞ ELECTRICAL INLET 400 600 300 ELEKTRİK GİRİŞ ELECTRICAL INLET G6F100E ELEKTRİK GİRİŞ ELECTRICAL INLET 600 600 300 ELEKTRİK GİRİŞ ELECTRICAL INLET G6F200E 730 900 400 ELEKTRİK GİRİŞ ELECTRICAL INLET G7F100E ...

Page 7: ...ined in this manual operating instructions operation and maintenance of the device contains the latest information on your device The manufacturer accepts no responsibility for damage or injury which may result from failure to follow the instructions in this manual use outside of the intended use unauthorized repair unauthorized modifications to the device or use of spare parts not approved by the...

Page 8: ...00V AC 3N PE 1800W 400V AC 3N PE C2 C1 K1 R1 S1 F1 K1 L3 PE N L2 L1 M A1 S EMNİYET SWİTCH SAFETY SWITCH F1 LİMİT THERMOSTAT SAFETY THERMOSTAT M GIRIŞ KLEMENSI INLET CLAMP R ISITCI HEATER C LAMBA LIGHT INDICATOR A ŞALTER MAIN SWITCH F2 F2 THERMOSTAT SAFETY THERMOSTAT ...

Page 9: ...PE 2x1800W 400V AC 3N PE C2 C1 K1 R2 S1 F1 K2 L3 PE N L2 L1 M A1 S EMNİYET SWİTCH SAFETY SWITCH F1 LİMİT THERMOSTAT SAFETY THERMOSTAT M GIRIŞ KLEMENSI INLET CLAMP R ISITCI HEATER C LAMBA LIGHT INDICATOR A ŞALTER MAIN SWITCH F2 F2 THERMOSTAT SAFETY THERMOSTAT K2 S1 F1 F2 C3 R1 K1 ...

Page 10: ...ESCRIPTION SIGN PRODUCT NAME DETECTED Name Appellation CUSTOMER NAME CUSTOMER COMPLAINT DETECTION TYPE CORRECTIVE PREVENTIVE ACTIVE FORM OPTIMIZATION REQUEST DESCRIPTION Note If required you can send it to our company by viewing the form above or by post ...

Page 11: ...cate We continue to contribute to the environment using recycled paper Manufacturer Gürçelik Dayanıklı Tüketim Mamülleri Mut Ins Tur Tar San Tic Ltd Sti Adress Bahçelievler Mahallesi Sakarya Cad No 11 Yazıbaşı Torbalı İZMİR Phone 90 232 853 92 00 Web www kusina com tr www gurcelikas com E mail info kusina com tr is a brand ...