Hz  Input  sensitivity  varies  automatically  with 
voltage  range  selected.    6V  range  has  the 
highest & 1000V  range  has  the  lowest. Press  

SELECT   

button  momentarily  toggles  to  higher 

resolution 

VFD-Hz

  in  main  display.    The  display 

shows  the  selected  voltage  range  for  about  one 
second before displaying Hz readings.  Pressing 
the 

RANGE

  button  momentarily  repeatedly  to 

display and select any other voltage range.  If the 
Hz  reading  becomes  unstable,  select  higher 
voltage  range  to  avoid  electrical  noise.    If  the 
reading  shows  zero,  select  lower  voltage  range 
for better sensitivity.

17

KUSAM-MECO                                                                                April 2011

®

+Hz

Function  defaults  at 

VFD-ACV

.    By  default, 

voltage is set at 600V & 1000V two auto-ranges to 
best  cope  with  most  Variable  Frequency  Drives 
(VFD)  measurements.    High  noise-rejection 
frequency  measurement  algorithm  and  Low-pass 
filter  circuit  are  permanently  bundled  with  all 
voltage  and  frequency  function-ranges  within  this 
rotary-switch  position.    Press  the 

RANGE

  button 

momentarily  to  select  other  ranges  only  when 
needed.

5ms-MAX

VFD

Hz

V

V

Hz

V

EF

OFF

MAX

9A

FUSED

MAX 0.6A

FUSED

A

mA

m

A

COM

W

V

1.082

SELECT RANGE

HOLD

300V   CAT IV
600V   CAT III
1000V CATII

MAX 

H

C

A

Hz

mA

Hz

m

A

Hz

mV

Hz

kHz

AUTO

Summary of Contents for KM 711

Page 1: ...s Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insu...

Page 2: ...circuit it You can therefore send high current through your meter and severely damage it Unless the meter has a fused input you can even get an explosion or fire Even if you correctly insert your DMM...

Page 3: ...by the manufacturer the protection provided by the instrument may be impaired The meter is intended only for indoor use The meter protection rating against the users is double insulation per IEC61010...

Page 4: ...These voltage levels pose a potential shock hazard to the user Do not touch test lead tips or the circuit being tested while power is applied to the circuit being measured Keep your fingers behind th...

Page 5: ...isplay LCD Polarity Automatic Update Rate 5 per second nominal Operating Temperature 0 C to 40 C Pollution degree 2 Altitude Operating below 2000m Relative Humidity Maximum relative humidity 80 for te...

Page 6: ...ry X 2 Dimension 186 L X 87 W X 35 5 H mm 198 L X 97 W X 55 H mm with holster Weight 340gm 430gm with holster Accessories Test leads pair User s Manual Holster Batteries installed 7 KUSAM MECO April 2...

Page 7: ...KUSAM MECO April 2011 RESISTANCE 600 0 W 0 8 rdg 8dgts 6 000 KW 60 00 KW 600 0 KW 6 000 MW Open Circuit Voltage 0 45VDC typical 0 6 rdg 4dgts 1 5 rdg 5dgts Accuracy Resolution Range 60 00 MW 2 5 rdg 5...

Page 8: ...A 1 9 00 A 0 045V A 600 0 m A 6000 m A 60 00 mA 600 0 mA 6 000 A 1 9 00 A 0 1 m A 1 m A 0 01 mA 0 1 mA 0 001 A 1 0 01 A 11 KUSAM MECO April 2011 Accuracy 0 2 4d 1 VFD sensitivity linearly decreases f...

Page 9: ...eep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Top end of the meter Probe Contact EF Detection For more precise indication of live wires such as distinguish...

Page 10: ...Input Jack for 10A 20A for 30sec current function 15 KUSAM MECO April 2011 5ms MAX VFD HzV V Hz V EF mV Hz m A mA Hz Hz A Hz OFF MAX 9A FUSED MAX 0 6A FUSED 300V CAT IV 600V CAT III 1000V CATII MAX SE...

Page 11: ...g becomes unstable select higher voltage range to avoid electrical noise If the reading shows zero select lower voltage range for better sensitivity 17 KUSAM MECO April 2011 Hz Function defaults at VF...

Page 12: ...highest available sensitivity for logic level frequency measurements All the voltage and frequency function ranges within this rotary switch position are set at regular frequency response without empl...

Page 13: ...V 600V CAT III 1000V CATII MAX H C A Hz mA Hz m A Hz mV Hz AUTO mV 1 SELECT 60 0 Hz 21 KUSAM MECO April 2011 W 5ms MAX VFD HzV V Hz V EF OFF MAX 9A FUSED MAX 0 6A FUSED A mA m A COM W V 000 6 SELECT R...

Page 14: ...s must be disconnected from the circuit to obtain an accurate measurement reading Defaults at W Press SELECT button momentarily to select continuity function which is convenient for checking wiring c...

Page 15: ...Hz mV Hz Electric Field EF Detection Defaults at E F Function Press SELECT button momentarily 2 times to select E F function The meter display E F when it is ready Signal strength is indicated as a se...

Page 16: ...ro select lower current range for better sensitivity 27 KUSAM MECO April 2011 5ms CREST MAX capture mode Press 5ms MAX HOLD button for 1 second or more to activate CREST MAX capture Instantaneous Peak...

Page 17: ...D feature freezes the display for later view Press the HOLD button momentarily to toggle the HOLD feature 29 KUSAM MECO April 2011 Trouble Shooting If the instrument fails to operate check batteries a...

Page 18: ...roof version without battery access door Loosen the 2 screws from the battery access door of the case bottom Lift the battery access door and thus the battery compartment up Replace the battery Re fas...

Page 19: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO G 17 Bharat Industria...

Reviews: