This series of  instruments  is designed  to  comply  with  IEC1010 
(International  Electro-technical  Commission  promulgated  safety 
standards), before use, please read the  safety precautions.
1. When measuring the voltage, please  input  the limit  voltage of 
DC 1000V or AC 750V rms.
2. The voltage below 36V is safe voltage. When measuring above 
36V DC &  25V AC  voltage, check  whether  test  pen  is  reliable 
contact  or  right connected  or good  insulation properly,  whether
insulation is good & so on, in order to avoid electric shock.
3. When Change function & range, test pen should leave the test
point;
4. Select  the correct  function  & range,  guard against  accidental 
operation, the  series of  instruments  although  there  is full-range 
protection, but for safety reasons, you still pay more attention.
5. When measuring current, do not input batteries more than 10A.
6. Safety symbol description,  “     ”  Exist dangerous voltage,
 “        ” Ground, “      ” Double insulation, “     ” Operator must refer
 to the instruction manual, “     ” Low voltage symbol.

+

-

I. 

Overview :

The 6000 counts is a pocket-sized 3-5/6 bit automatic

digital instrument.  Is  a  stable  performance, high  precision, high 

reliability clear readings, and overload  protection.  With AAA 1.5V 

battery-driven.  The instrument  uses  a large screen LCD  display, 

boost  power  supply, even in  the 2.3V  low  battery  edge, it  can 

guarantee the backlight high brightness, the table is easy to carry, 

is a vast  number of users extremely like the instrument, the back-

light can be bright can be automatically turned off after 15seconds.

This series of instruments can be used to measure the DC Voltage

and AC Voltage DC Current & AC Current, Resistance, Capacitan

ce

diode, Continuity Test, Square-wave output, Frequency measurement

& True RMS measurement & other parameters. Is a ideal tool for 

the laboratory, factory, radio enthusiasts & families.

I. SAFETY  :

02

FEATURES :

í

 

Backlight Display

í

 

Pulse Output

í

 Non-Contact Voltage 

     Measurement (NCV)

í

 

Sensing : 

True RMS 

í

 

Display :

 3-5/6 digits 6000 counts liquid crystal LCD display

í

 Maximum Display :

 5999 counts

í

 Sampling Time :

 about 3 times / second

í

 Operating Temperature : 

0°C to 40°C, Relative Humidity <80%

í

 Measurement :

 Double integral A/D conversion.

í

 Overrange Display : 

‘OL’ 

í

 Automatic Polarity display.

í

 Auto Power Off : 

about 15 minutes when no signal.

í

 Low Battery Indication : 

Below 2.3V

í

 Power Supply : 

1.5V AAA  x 2 battery.

í

 Dimension : 

Approx.142(L)mm x 70(W)mm x 32(H)mm

í

 Weight :

 Approx. 205gm (including battery).

í

 Accessories :

 

User Manual, Test leads & Battery.

í

 Flash Light

í

 

Data Hold

í

 MAX / MIN & Rel Zero

GENERAL SPECIFICATIONS

●  

SAFETY :

     Complies with the safety requirements IEC1010 CAT III 600V.

Summary of Contents for KM 60-T

Page 1: ...s Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insu...

Page 2: ...TRMS DIGITAL MULTIMETER MODEL KM 60 T TABLE OF CONTENTS TITLE PAGE NO I Safety II Electrical Specifications III Troubleshooting IV Instrument Layout V Test Certificate VI Warranty 01 02 03 19 23 24...

Page 3: ...battery driven The instrument uses a large screen LCD display boost power supply even in the 2 3V low battery edge it can guarantee the backlight high brightness the table is easy to carry is a vast n...

Page 4: ...s Accuracy Resolution Input Impedance 10MW Overload Protection 6V range is 550V DC or AC peak The rest is 1000V DC or 750V AC Peak Maximum input voltage 750V AC RMS or 1000V DC The specific operation...

Page 5: ...it 3 When measuring high voltage circuit pay special attention to avoid electric shock 4 After completing all measuring operations disconnect the test leads from the circuit under test 06 50 00 D A SE...

Page 6: ...00mA 250V Speed Glass Fuse DC CURRENT mA 600 mA 6000 mA 0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 08 The specific operation is as follows 1 Insert the black test lead into the COM socket In...

Page 7: ...n the range switch to the corresponding DC AC mA gear trigger SELECT to select AC m A and then put the meter into the circuit under test The measured current value and the current polarity of the red...

Page 8: ...0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 12 highest range then according to the display value to the corresponding file such as the screen display 0L that has exceeded the range needed to...

Page 9: ...rst turn off the power then disconnect the test leads the measured circuit connection Especially to high current measurement 6 It is forbidden to input more than 36V DC 25V AC Voltage between the curr...

Page 10: ...0 nF 6 mF 60 mF 600 mF 30 mF 6 mF 15 NOTE 1 When measuring low resistance the table will bring the internal resistance in order to obtain accurate readings you can firstly record the short circuit val...

Page 11: ...e 3 Please test the capacitor capacity before the capacitor should be fully disharged to prevent damage to the fuse and instrumentation 4 Unit IF 1000mF 1mF 1000 F 1uF 1000nf 1nF 1000p 18 Overload Pro...

Page 12: ...ELECT HOLD MAX MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 750V DC 1000V DC 10A COM VWHzmA mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out 1 2 3 4 5 6 7 8 9 20 The operat...

Page 13: ...mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out NCV MEASUREMENT 22 If your instrument does not work the following method can help you solve the general problem if the fault still can not b...

Page 14: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE KUSAM MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INC...

Reviews: