Press  the  

SELECT

  button  for 1 second  or  more to toggle the LCD 

backlight.  The  backlight  will  also  be  turned  off  automatically  after 
32 seconds to extend battery life.

Relative-Zero (∆) mode

Backlighted LCD display (Model KM 2777)

Relative-Zero   allows   the  user   to   offset   the  meter   consecutive 
measurements  with  the  main  display  displaying  reading  as  the 
reference  value.  Press  the 

REL

  button  momentarily  and  release  to 

toggle Relative-Zero mode.

Press the 

RANGE

 button momentarily and release to select manual-

ranging,  and  the  meter  will  remain  in  the  range  it  was  in,  the  LCD 

 AUTO

  turns off.  Press the button again to step through the ranges.

Press  and  hold  the  button  for  1  second  or  more  and  release  to 
resume auto-ranging.

Manual or Auto-ranging

Note: manual-ranging feature is not available in 

Hz

 and        function

ranges.

Press  the  

RANGE 

 button  while turning  the meter on to temporarily 

disable  the  Beeper  feature.  Turn  the  rotary  switch  OFF  and  then 
back on to resume.

Set Beeper Off

 

- 24 -

Non-Contact  EF-Detection: An  antenna  is  located along the top-

right  end  of  the  clamp  jaw,    which  detects  electric  field  surrounds 
energized conductors. It is ideal for tracing live wiring  connections, 
locating  wiring  breakage  and  to  distinguish  between  live  or  earth 
connections.

Probe-Contact  EF-Detection:  For  more  precise indication of live 

wires, such as distinguishing between live and ground connections, 
use the Red (+) test probe for direct contact measurements.

The  instrument  equips with an optical isolated interface port at the 
meter  back  for  data  communication.  Optional  purchase  PC 
interface kit BRUA-19X is required to connect the  meter to the PC 
computer RS232 or USB ports. Press and  hold the 

HOLD

 button 

while turning the meter on to enable meter PC-COMM output.

The hold feature freezes the display for later view. Press the 

HOLD

 

button momentarily and release to toggle the hold feature.

PC computer interface capabilities

Hold

Press 

CREST

 (HOLD) button for one second or more and release 

to  activate  CREST-MAX  capture  (Instantaneous  Peak-Hold)  mode 
to capture signal peak of  voltage or current  in  duration as short as 
5ms.  The  LCD  “

C

”  &  “

MAX

”  turn  on.  Press  again  the  button 

momentarily and release can toggle the combination use of HOLD 
feature. Press the button for 1 second or more and release to exit 
CREST-MAX  capture  mode. Auto-ranging  and Auto-Power-Off  are 
disabled automatically in this mode.

5ms CREST-MAX capture mode

Summary of Contents for KM 2777

Page 1: ...otherwise specified Power supply Standard 1 5V AAA Battery x 2 Power Consumption Typical 14mA for Current function 5 2mA for others APO Timing Idle for 34 minutes APO Consumption 10m A typical Dimens...

Page 2: ...olution Range 4 0 rdg 5dgts 2 1 Accuracy 600 0 m F 2000 m F 1 Accuracies with film capacitor or better 2 Temperature Coefficient 0 25 x specified accuracy C 0 C 18 C or 28 C 40 C 10 pF 100 pF 1 nF 10...

Page 3: ...faster than their rated life 2 Circuit breakers to trip prematurely 3 Fuses to blow 4 Neutrals to overheat due to triplen harmonics present on the neutral 180Hz 5 Bus bars and electrical panels to vib...

Page 4: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Page 5: ...e Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Batte...

Page 6: ...AC DC TRMS Clamp On Multimeter with VFD EF Detection PC Interface MODEL KM 2777...

Page 7: ...e building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT The meter protection rating against the users is double insulation per IEC EN61010 1 2nd Ed UL61010...

Page 8: ...st leads connectors and probes for damaged insulation or exposed metal before using the instrument If any defects are found replace them immediately Only use the test lead provided with the equipment...

Page 9: ...specified 04 Power supply Standard 1 5V AAA Battery x 2 Power Consumption Typical 14mA for Current function 5 2mA for others APO Timing Idle for 34 minutes APO Consumption 10mA typical Dimension 264...

Page 10: ...s 40Hz 50Hz 60Hz 400Hz 200 0 A 0 500 A 500 1000 A 3 0 rdg 5dgts 3 5 rdg 5dgts 1000 2000 A Unspecified 100 mA 1 A 1 A 100 mA 1 A 1 A 1 A 06 DC ACA CURRENT Clamp on 1 2 Accuracy Resolution Range True RM...

Page 11: ...1 2 rdg 5dgts Input Impedance 10MW 50pF nominal 1 mV 10 mV 100 mV 1 V 08 VFD_ ACV with Low Pass Filter 6 000 V 4 rdg 80dgts 60 00 V 600 0 V 1000 V 1 Accuracy Resolution Range 10Hz 20Hz 20Hz 200Hz 2 20...

Page 12: ...pacitor or better 2 Temperature Coefficient 0 25 x specified accuracy C 0 C 18 C or 28 C 40 C 10 pF 100 pF 1 nF 10 nF 100 nF 1 mF 11 TM AUTOCHECK _DCV Accuracy Resolution Range TM AutoCheck Lo Z DCV T...

Page 13: ...6 000 V 1 5 rdg 5dgts 60 00 V 600 0 V 1000 V 1 Accuracy Resolution Range 50Hz 60Hz 1 mV 10 mV 100 mV 1 V TM AUTOCHECK _ACV TM AutoCheck Lo Z ACV Threshold 1 5V 50 60Hz nominal TM AutoCheck Lo Z ACV i...

Page 14: ...w trigger for opening the clamp jaw 15 TM This innovative AutoCheck feature automatically selects Hz measurement function of ACV DCV or Resistance based on the input via test leads CAUTION Before and...

Page 15: ...on high voltage hard signals LoZ displays on the LCD to remind the users of being in such low impedance mode Peak initial load current while probing 1000VAC for example can be up to 566mA 1000V x 1 41...

Page 16: ...around conductor s of only one single pole of a circuit for load current measurement Make sure the jaws are completely closed or else it will introduce measurement errors Enclosing conductor s of more...

Page 17: ...900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse the test leads connections reverse...

Page 18: ...o use a plug adapter bkb32 optional purchase with banana pins to type k socket to adapt other type k standard mini plug temperature probes F C 1 SELECT 23 In Voltage or Current function press the EF b...

Page 19: ...ounds energized conductors It is ideal for tracing live wiring connections locating wiring breakage and to distinguish between live or earth connections Probe Contact EF Detection For more precise ind...

Page 20: ...heck batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual Trouble Shooting If the instrument voltage resistance input terminal has...

Page 21: ...oducts to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or...

Reviews: