An ISO 9001:2008 Company
®
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.:
022 -24156638,
Tel. :
022-24124540, 24181649,
Fax :
022 - 24149659
Email :
Website :
www.kusamelectrical.com
An ISO 9001:2008 Company
®
All Specifications are subject to change without prior notice
Chhaya Computer/D:/Chhaya/My Document/Chhaya/backup/Catlogs/New cat/KM 2009.cdr
AC / DC DIGITAL CLAMPMETER WITH
DATA LOGGING FUNCTION & PC INTERFACE
Model - KM 2009
GENERAL SPECIFICATIONS :
ï
Sensing :
Average sensing
ï
Jaw Opening Size :
40mm
ï
Function :
Measurement of AC / DC current,
upto 600A & On-line
measurement.
ï
Display Size :
32mm x 15mm
ï
Test Mode :
Clip-on CT, Integral mode.
ï
Display Mode :
Four Digit LCD display.
ï
LCD Dimension :
35mm x 21.5mm
ï
Sampling Rate :
About 2times/s
ï
AC/DC Current Range :
0.0A ~600A
ï
Frequency Range :
45Hz ~ 400Hz
ï
Resolution :
0.1A
ï
Accuracy :
±2%rdg + 3dgts
ï
Line voltage :
Line test under AC600V
ï
Data Hold :
Display shows “
DH
” symbol.
ï
Out of Range :
Display shows “
OL
” symbol.
ï
Data Storage :
99 groups, all used when
display “FULL”
Carrying Case, Battery installed,
User's Manual, RS232 PC Interface CD.
ACCESSORIES :
ï
Power Consumption :
about 10mW
ï
Peak Hold :
Press “HOLD” without release,
the meter will show the peak value.
ï
Battery Voltage :
“ ” indicating the battery
voltage is lower then 7.2V. Then the battery
have to be changed.
ï
Operating Temperature and Humidity :
0
0
0 C ~ 40 C : below 80% R.H.
ï
Storage Temperature and Humidity :
0
0
-
10 C ~ 60 C : below 70%rh
ï
Insulation Strength :
AC 2kV/rms
(between the alloy of the clamp & housing)
ï
Auto Power Off :
5 minutes after power on,
it will power off automatically to lower the
power consumption.
ï
Power :
Standard 9V battery.
ï
Dimension :
175(W) x 70(H) x 38(T)mm
ï
Weight :
Approx. 180g (with battery)
ELECTRICAL SPECIFICATIONS : KM 2009
Range
Resolution
Accuracy
0.0A ~ 600A
±(2% rdg + 3 dgts)
AC CURRENT
DIAGRAM OF MEASURING CURRENT
(Reference Diagram)
IEC1010-1, IEC1010-2-032,
pollution degree 2, CAT III (600V)
SAFETY :
0.1 A
Measuring DC current
Test current consumption
Measuring charging current:
12 V DC
Accumulator
Solar panel power
Device powered
by DC
+
-
+
-
I
+
Wire Position
L
N
Measure AC line current
Measure consumption
Range
Resolution
Accuracy
0.0A ~ 600A
±(2% rdg + 3 dgts)
DC CURRENT
0.1 A
FOR SOLAR APPLICATIONS