background image

®

®

AN ISO 9001:2008 COMPANY

MODEL - KM 117A

DIGITAL COATING

THICKNESS GAUGE

OPERATION MANUAL

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649. 

Fax :

 (022) 24149659

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

              www.kusam-meco.co.in

®

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

Summary of Contents for KM 117A

Page 1: ...Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency C...

Page 2: ...GAUGE MODEL KM 117A TABLE OF CONTENTS TITLE PAGE NO I II Features VI Introduction III Safety Information V Product Use Maintenance VIII Test Certificate IX Warranty IV Specifications Measurements VII...

Page 3: ...in an environment where it will be directly illuminated by sunshine or where it condensation If you do it may be deformed its insulation may be damaged or it may no longer function according to speci...

Page 4: ...r away from the interfered source at least 30cm B Electromagnetic Field Strength unit mini Gauss Electromagnetic Source Cellular Phone Charger Notebook Power Supply LCD Display Fan Reading Lamp Any pr...

Page 5: ...ery Accessories User Manual Battery carrying case 2 Electrical Specifications Detectable Substrate Material Ferrous metal iron steel Thickness Range 0 80 0mils 0 2000m m Display Resolution 0 1mils 1m...

Page 6: ...ress the button for 2 seconds to clear Calibrating Point BASE 2S ZERO During measure mode DEL ESC The three buttons are disabled During setting mode The two buttons are disabled 2S BASE 2S ZERO 08 4 T...

Page 7: ...kness is out of range the meter shows CAUTION Keep the sensing tip of the meter away from any substrate or any magnetic field 4 When the alarm is activated measured exceed Hi Limits or Lo Limits LCD d...

Page 8: ...CAL h Into Hi value adjustments of the two point calibration press or button to adjust reading when it display the desired value press button to confirm MENU 12 Press the tip of the Gauge to contact c...

Page 9: ...lete or yes press button to return to browse previous records MENU yes press button to delete record and return to the measuring mode MENU Fe m m MEM ec o MAX 14 al Alarm Setting Fe m m al In this mod...

Page 10: ...et the desired value press button to confirm the Hi Limits alarm and return to measuring mode MENU Alarm setting Maximum is 2000m m 78 7 mils Minimum is 0 m 0 mils m 16 u Unit Selecting In this mode p...

Page 11: ...range the meter shows 18 VII MAINTENANCE Installing and Replacing Battery 1 Power is supplied by 2pcs 1 5V AAA size 2 The appears in the display when battery replacement is needed 3 Remove the batter...

Page 12: ...authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altere...