CLAMP-ON TYPE
EARTH RESISTANCE TESTER
MODEL - KM 1120 / KM 1220
Preliminary Data.
—
Display :
4 digit LCD Backlight Display.
—
Jaw Opening :
65 x 32 mm.
—
Span of Jaw :
32 mm.
—
Structural Feature :
In the jaw way.
o
—
Operating temperature :
-10 C ~ 55 C
—
Relative humidity :
10% ~ 90%RH
—
Protection grade :
double insulation
—
Range selection :
Automatic
—
External Magnetic Field :
< 40A/m
—
External Electric Field :
<1V/m
—
Sampling Time :
1 second
—
Measurement Resistance Frequency :
>1kHz
—
Max. Resistance Measurement Resolution :
0.001
W
—
Resistance Measurement Range :
0.010 ~ 1000
W
—
Current Measurement Range :
0.00 - 20.0A (KM 1220)
—
Measured Current Frequency :
50 / 60Hz (KM 1220)
—
Storable Measurement Data :
99 units (KM 1220)
—
Setting range of Resistance Alarm Critical value :
1 - 199
W
(KM 1220)
—
Setting Range of current Alarm Critical Value :
1 - 499mA (KM 1220)
—
Power Supply :
6VDC ( 4 x 5 Alkaline Battery).
—
Dimension :
285 (L) X 85 (W) X 56 (T)mm.
—
Weight :
Approx. 1160g. (including batteries)
o
W
GENERAL SPECIFICATIONS :
ELECTRICAL SPECIFICATIONS :
Measurement
Range (
W
)
Resolution
(
W
)
Accuracy
(
W
)
0.010~ 0.099
0.001
±(1% + 0.01
W
)
1.0 ~ 49.9
50.0 ~ 99.5
100 ~ 199
200 ~ 395
400 ~ 590
600 ~ 1000
0.1
0.5
1
5
10
20
±(1% + 0.1
W
)
±(1.5% + 0.5
W
)
±(2% + 1
W
)
±(5% + 5
W
)
±(10% + 10
W
)
±(20% + 20
W
)
RESISTANCE
Measurement
Range (
W
)
Resolution
(
W
)
Accuracy
(
W
)
0.00 - 99mA
100 - 299mA
0.30 - 2.99A
3.00 - 9.99A
10.00 - 20.00A
1mA
1mA
10mA
10mA
10mA
±(2.5% + 5mA)
±(2.5%+10mA)
±(2.5%+0.1A)
±(2.5%+0.2A)
±(2.5%+0.3A)
CURRENT RANGE MEASUREMENT (KM 1220)
ETCR Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance
measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and
industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect
the ground wire without auxiliary electrode, which means safer and faster. KUSAM-MECO Clamp Earth
Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in
the occasion where traditional methods are unworkable; KUSAM-MECO Clamp Earth Resistance Tester
measures the integrated value of ground resistance and resistance lead. Tester can measure the leakage
current of ground wire.
An ISO 9001:2008 Company
0.10~ 0.99
0.01
±(1% + 0.01
W
)
NEW
All Specifications are subject to change without prior notice.
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.:
022-24156638,
Tel. :
022-24124540, 24181649,
Fax :
022-24149659
Email :
Website :
www.kusamelectrical.com
An ISO 9001:2008 Company
®
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM 1120/km 1220.cdr
Summary of Contents for KM 1120
Page 5: ... 01 02 ...
Page 6: ... 03 04 ...
Page 7: ... 05 06 ...
Page 8: ... 07 08 ...
Page 9: ... 09 10 ...
Page 10: ... 11 12 ...
Page 11: ... 13 14 ...
Page 12: ... 15 16 ...
Page 13: ... 17 18 ...
Page 14: ... 19 20 ...
Page 15: ... 21 22 ...
Page 16: ... 23 24 ...
Page 17: ... 26 25 ...
Page 18: ... 28 27 ...
Page 19: ... 30 29 ...