Kusam-meco KM 078 Instructions Manual Download Page 9

®

®

08

DC+AC Voltage (with Digital Low-pass Filter) :

Input Impedance : 10M

W

, 100pF nominal

Accuracy

Resolution

Range

600.0  V

±(1.2%rdg + 7dgts)

0.1     V

DC, 50Hz ~ 60Hz

DC Voltage :

Input Impedance : 10M

W

, 100pF nominal

600.0  V

±(1.0%rdg + 5dgts)

Accuracy

Resolution

Range

0.1     V

AC Voltage (with Digital Low-pass Filter) :

Input Impedance : 10M

W

, 100pF nominal

Accuracy

Resolution

Range

600.0  V

±(1.0%rdg + 5dgts)

0.1     V

50Hz ~ 60Hz

Resistance :

Open Circuit Voltage : 1.0VDC typical

600.0   

6.000 K

60.00 K

W

W

W

±(1.0%rdg + 5dgts)

Accuracy

Resolution

Range

0.1 

1    

10  

W

W

W

Capacitance :

1)

 Accuracies with film capacitor or better.

200.0 

m

F

2500  

m

F

±(2.0%rdg + 4dgts)

1)

Accuracy

Resolution

Range

0.1 

m

F

1    

m

F

09

Indication : Bar-graph  segments &  audible beep tones proportional to 
the field strength.      Detection Frequency : 50/60Hz.
Detection Antenna : Inside the top side of the stationary jaw.
Probe-Contact EF-Detection : For more precise indication of live wires, 
such as distinguishing between live and ground connections,  use  one 
single probe to test via  terminal  COM  for  direct contact EF-Detection
with best sensitivity.

Non-Contact EF-Detection

 :

20V (tolerance : 10V~36V)

55V (tolerance : 23V~83V)

110V (tolerance : 59V~165V)

220V (tolerance : 124V~330V)

440V (tolerance : 250V~1000V)

Bar-Graph Indication

Typical Voltage

-

- -

- - -

- - - -

- - - - -

PEAK-rms (ACV & ACA) :

80ms to >90%

Response

Accuracy : 

1)

 DC-bias, if any, not more than 50% of Sine RMS.

±(1%rdg + 5dgts)

Hz Line Level Frequency :

600   V

TM

60     A (AmpTip )

60     A

600   A

5.00Hz~999.9Hz

50.00Hz~400.0Hz

50.00Hz~400.0Hz

Range

1)

Sensitivity
(Sine RMS)

Function

50  V

20  A

20  A

Audible Continuity Tester :

Between 10

W

 and 250

W

.

32ms approx.

Audible Threshold

Response time

Summary of Contents for KM 078

Page 1: ...with DC Zero mode on DCA DC ACA ranges Temperature Coefficient Nominal 0 15 x o o o o o specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Size Battery X...

Page 2: ...M AMPTIP CLAMP ON DC CURRENT 1 2 3 Accuracy Resolution 2 0 rdg 5dgts 0 01 A 60 00 A 1 Induced error from adjacent current carrying conductor 0 01A A 2 Specified with DC Zero mode applied to offset the...

Page 3: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Page 4: ...Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Ca...

Page 5: ...s for equipment intended to be supplied from the building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT OVERVOLTAGE CATEGORY III CAT III is for equipment in...

Page 6: ...I 600V or better This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in...

Page 7: ...cessories Test leads set User Manual Soft carrying case V SPECIFICATIONS 05 Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C22 2 No 61010 1 Ed 3 IEC EN61010 2 032 Ed...

Page 8: ...dg 5dgts 10 mA 50Hz 60Hz Diode Tester Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typically 2 000 V 1 5 rdg 5dgts 1 Accuracy Resolution Range 1 mV 07 1 Induced error from adjacent current...

Page 9: ...ep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Inside the top side of the stationary jaw Probe Contact EF Detection For more precise indication of live wires...

Page 10: ...DCA polarity at where best current accuracy is specified 11 VII OPERATION WARNING Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to de...

Page 11: ...I 600V CAT IV 300V PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V EF Live Ground 13 CAUTION WARNING for Non Invasive Clamp on Curr...

Page 12: ...HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 6008 Hz SELECT 1 HZ Non Invasive Regular Current Functions ACA DCA DC ACA Hz Input is made via the clam...

Page 13: ...ECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 0602 W V AUTO PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A...

Page 14: ...meter consecutive measurement with the main display displaying reading as the reference value LCD turns on Press the button for one second or more to toggle Relative Zero mode HOLD 80ms PEAK RMS mode...

Page 15: ...e like open fuses to protect the user and the instrument Most measuring functions through this terminal might then be open circuit Such components should only be replaced by qualified technician Refer...

Page 16: ...horized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered ne...

Reviews: