background image

G-17, Bharat  Industrial  Estate,  T. J.  Road,  Sewree (W),  Mumbai -  400 015. INDIA.

Sales Direct.:

 022-24156638,     

Tel. : 

022-24124540, 24181649,      

Fax : 

022-24149659

Email :

 [email protected],                                  

Website :

 www.kusamelectrical.com

All Specifications are subject to change without prior notice

?

   

?

   

?

   

?

   

 

TM

AmpTip  low-current range calibrated at 

     Jaw-tip for slim-conditions for accurate readings

MAX/MIN/AVG Recording mode (Auto ranging)

VFD-V & Hz for fundamental V/Hz of most 

     Variable-Frequency-Drives.

Display Hold & Non-Contact EF-Detection (NCV)

SPECIAL FEATURES :

GENERAL SPECIFICATIONS :

í

Sensing : 

AC+DC; 

í
í
í
í
í
í

í
í

 

 

 

 

 

 

 

 

 

True RMS

0ºC to 40ºC

Maximum relative humidity 

     80% for temperature up to 31ºC decreasing 

     linearly to 50% relative humidity at 40ºC

Jaws Opening size :

 35mm Max.

Display :

 3-5/6 digits 6000 counts

Update Rate :

 5 per second nominal

Polarity :

 Automatic

Operating Temperature : 

Relative Humidity :

 

Altitude :

 Operating below 2000m

Storage Temperature :

 -20°C ~ 60°C,  \

     <80% R.H. (with battery removed)

SAFETY :

?

   

?

   

?

   

?

   

Safety :

 

Measurement Category :

 

Overload Protection :

      

Pollution Degree :

 2

Double insulation per UL/IEC/EN61010-1 

      Ed. 3, IEC/EN61010-2-033 Ed.1,CAN/CSA C22.2 

      No.61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 3 & 

      IEC/EN61010-031 Ed. 1.1

CAT III 600V AND 

      CAT IV 300V AC & DC

Current & Hz functions via jaws : 600ADC/AC rms 

      at <400Hz.

      Voltage : 660VDC rms

      Other functions via terminals : 600VDC/ VAC rms

AC+DC TRUE RMS DIGITAL CLAMPMETER WITH 

VFD, EF-DETECTION, AMPTIP FUNCTION FOR 

LOW CURRENT MEASUREMENT 

Preliminary Data

NEW

®

An ISO 9001:2008  Company

MODEL KM 078

ACCESSORIES : 

Test leads set, Users Manual, Carrying case.

®

An ISO 9001:2008  Company

Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 076.cdr

?

   

?

   

?

   Auto-ranging 

Back-lighted easy-to-read LCD display

Fast 80ms Peak-RMS mode to capture 

      in-rush currents

Relative mode with DC-Zero 

     mode on DCA, DC+ACA ranges

í

í
í
í

í

í
í
í

 

 

 

 

 

 

 

 

Temperature Coefficient :

 Nominal 0.15 x 

o

o

o

o

o

     (specified accuracy) /  C @ (0 C –– 18 C or 28 C –– 40 C), 

      or otherwise specified

Power Supply : 

Standard 1.5V AAA Size Battery X 2

Power Consumption :

 typical 13mA

Low Battery :

 

APO timing :

 Idle for 32 minutes

APO Consumption :

 typical 5

m

A

Dimension :

 223(L) x 76(W) x 37(H)mm

Weight :

 approx 234 gms.

Below approx. 2.85V for Capacitance & Hz 

                              Below approx. 2.5V for other functions

?

   

?

   

?

   

?

   

E.M.C. :

 

Transient Protection :

  6.0kV (1.2/50

m

s surge)

Rugged Fire retarded casing.

LVD EN61010-2-032/EN61010-2-032/EN61010-2-033 to CAT III 600V & CAT IV 300V

Meets EN61326-1 : 2006 (EN55022, EN61000-3-2,

      EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, 

      EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) :

      DCA and DC+ACA Functions, in an RF field of 1V/m :

      Total Accuracy = Specified Ac 20 digits at around 405MHz

     

Ohm Functions, in an RF field of 1V/m : 

                     Total Accuracy = Specified Ac 25 digits 

      Other Functions, in an RF field of 3V/m : 

                     Total Accuracy = Specified Ac 20 digits

ELECTRICAL  SPECIFICATIONS : KM 078

o

o

Accuracy is ± (% of reading number of digits) or otherwise specified, at 23 C ± 5 C

Maximum Crest Factor <2.5:1 at full scale & <5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding 

the specified frequency bandwidth for non-sinusoidal waveforms.

REGULAR CLAMP-ON AC CURRENT

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.01A/A

2)

 Maximum Crest Factor <2:1 at full scale & <4:1 at half scale.

3)

 Add 10d to the specified accuracy @ < 9A.

Range

1) 2)

   Accuracy

     Resolution

50Hz ~ 100Hz

±(1.8%rdg + 5dgts)

0.01    A

3)

60.00  A

0.1      A

600.0  A

100Hz ~ 400Hz

±(2.0%rdg + 5dgts)

0.01    A

3)

60.00  A

0.1      A

600.0  A

REGULAR CLAMP-ON DC CURRENT

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.01A/A

2)

 Specified with DC-Zero mode applied to offset the non-zero residual 

   readings, if any

3)

 Add 10d to the specified accuracy @ < 9A

Range

1) 2)

   Accuracy

     Resolution

±(2.0%rdg + 5dgts)

0.01    A

3)

60.00  A

0.1      A

600.0  A

Summary of Contents for KM 078

Page 1: ...with DC Zero mode on DCA DC ACA ranges Temperature Coefficient Nominal 0 15 x o o o o o specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Size Battery X...

Page 2: ...M AMPTIP CLAMP ON DC CURRENT 1 2 3 Accuracy Resolution 2 0 rdg 5dgts 0 01 A 60 00 A 1 Induced error from adjacent current carrying conductor 0 01A A 2 Specified with DC Zero mode applied to offset the...

Page 3: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Page 4: ...Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Ca...

Page 5: ...s for equipment intended to be supplied from the building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT OVERVOLTAGE CATEGORY III CAT III is for equipment in...

Page 6: ...I 600V or better This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in...

Page 7: ...cessories Test leads set User Manual Soft carrying case V SPECIFICATIONS 05 Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C22 2 No 61010 1 Ed 3 IEC EN61010 2 032 Ed...

Page 8: ...dg 5dgts 10 mA 50Hz 60Hz Diode Tester Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typically 2 000 V 1 5 rdg 5dgts 1 Accuracy Resolution Range 1 mV 07 1 Induced error from adjacent current...

Page 9: ...ep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Inside the top side of the stationary jaw Probe Contact EF Detection For more precise indication of live wires...

Page 10: ...DCA polarity at where best current accuracy is specified 11 VII OPERATION WARNING Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to de...

Page 11: ...I 600V CAT IV 300V PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V EF Live Ground 13 CAUTION WARNING for Non Invasive Clamp on Curr...

Page 12: ...HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 6008 Hz SELECT 1 HZ Non Invasive Regular Current Functions ACA DCA DC ACA Hz Input is made via the clam...

Page 13: ...ECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 0602 W V AUTO PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A...

Page 14: ...meter consecutive measurement with the main display displaying reading as the reference value LCD turns on Press the button for one second or more to toggle Relative Zero mode HOLD 80ms PEAK RMS mode...

Page 15: ...e like open fuses to protect the user and the instrument Most measuring functions through this terminal might then be open circuit Such components should only be replaced by qualified technician Refer...

Page 16: ...horized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered ne...

Reviews: