Press  "ZERO    " button to enter the 

relative mode and zero the display, and store the 

displayed as a reference value.  In relative mode, 

the "     " is displayed.

Press and hold down the "ZERO    " 

button for more than 2 seconds to exit the relative 

mode.

MAX/MIN Function Button

Press the "MAX/MIN" button to enter the 

MAX, MIN recording mode.  (Displays the 
Maximum reading, Minimum reading).

To pause max/min function without 

erasing stored values, press      .  The " HOLD " is 
displayed.  Press "MAX/MIN" button and hold down 
the "MAX/MIN" button for more than 2 seconds or 
turn the rotary switch to exit the MAX/MIN function.

H

1.

Press  the  "INRUSH"  button  before  the  inrush 

current    measurement    and    display   

shows    "- - - -".

2.

Press the trigger to open transformer jaws and 

clamp  on  to  one  conductor  only,  and  turn  on 

the motor.

3.

Read the INRUSH current directly from display.

Press and hold down the "INRUSH" button for 

more  than  2  seconds  to  disable/enable  the 

APO mode, and the "AUTO" turn off.

10

ZERO    Function Button

         Select the function 

frequency is to be checked i.e. "A" or "V".  Then 

press the 'Hz' button to measure the frequency of 

that function (A or V).

by rotary switch whose 

Display HOLD & PEAK Function Button

In display HOLD mode, the meter holds the 

reading on the display.

In PEAK mode, the meter displays the PEAK 

value of measured  value, PEAK function is enabled 

at ACV, DCV, ACA and DCA range.

Press        button to activate display HOLD.  The      

" HOLD " is displayed.

Press        button again to activate PEAK function.  

The "       " is displayed.

Press       button again to resume normal operation.

H

P

H

H

Hz  Function Button

11

Summary of Contents for 9999

Page 1: ...re current the same way as they measure voltage Remember you measure voltage across a circuit and current through a circuit When you use the current input your clamp meter becomes a low impedance circ...

Page 2: ...n Qty 1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 K Type Thermocouple 1 piece 4 Thermocouple Adaptor 1 piece In the event you find any Part missing or damaged please contact your dealer im...

Page 3: ...er F out side the o o o range of 18 to 28 C 65 F to 82 F Indoor use Altitude up to 2000m Safety Conformance All input are protected to EN61010 1 600V CAT III Pollution degree II EMC instrument unspeci...

Page 4: ...9999 W 0 1 1 Accuracy CAPACITANCE Range Resolution 0 to 999 9m F 0 1 m F Accuracy 5 rdg 10dgts Overload Protection 600V DC AC rms NOTE Supplied Thermocouple is suitable for o measurement upto 250 C f...

Page 5: ...pose a shock hazard 5 When using the probes keep your fingers behind the finger guards on the probes 6 Measuring voltage which exceeds the limits of the Clampmeter may damage the meter and expose the...

Page 6: ...cy Capacitance Temperature measurements and Continuity Diode Checks 8 FUNCTIONAL BUTTONS POWER ON THE METER Turn on the meter To select power on option Turn the rotaryswitch from zero position to any...

Page 7: ...s 2 Press the trigger to open transformer jaws and clamp on to one conductor only and turn on the motor 3 Read the INRUSH current directly from display Press and hold down the INRUSH button for more t...

Page 8: ...AX 999 9 VA m F W Hz 100 AUTO ZERO HOLD AC 0 25 50 75 AC P HOLD MAX MIN 11 m f m f Unit of Capacitance 12 A AC CURRENT MEASUREMENT 1 Set the range rotary switch to A 2 Press the trigger to open transf...

Page 9: ...III 600V DATA PEAK 600V MAX O Hz V A V O F W O C H B DC CURRENT MEASUREMENT Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz...

Page 10: ...V DATA PEAK 600V MAX O Hz V A V O F W O C H 16 1 Set the range rotary to position The is displayed 2 Turn off power to the circuit under test External voltage across the components causes invalid read...

Page 11: ...re Measurements K type Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz A CAT III 600V DATA PEAK 600V MAX O Hz V A V O F W O...

Page 12: ...the warranty period the same will be rectified by us free of charges provided the to and fro freight charges are borne by you This warranty extends only to the original buyer or end user customer of...

Page 13: ...MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE WHATSOEVER All transaction are subject to Mumbai Jurisdic...

Reviews: