SAFETY INFORMATION

The  following  safety  information  must  be 

observed  to  ensure  maximum  personal  safety 

during the operation of this meter.

1. 

 Do not use the meter if the meter or test leads 

  look  damaged,  or  if  you  suspect  that  the 

 meter is not operating properly.

2.

This  meter  is  not  recommended  for  high 

voltage  industrial  use,  for  example,  not  for 

measurements  of  440V  AC  or  600V  AC 

industrial  power  mains.    The  unit  is 

intended 

for  use  with  low  energy  circuits  to  600V 

AC/DC  or  high  energy  circuit  to  250V  AC  or 

DC.

3.   Turn  off  power  to  the  circuit  under  test  before 

cutting,  unsoldering,  or  breaking  the  circuit.   

Small amounts of current can be dangerous.

4.

Use  caution  when  working  above  60V  DC  or 

30V  AC  rms.    Such  voltages  pose  a  shock 

hazard.

5.

When  using  the  probes,  keep  your  fingers 

behind the finger guards on the probes.

6.

Measuring voltage which exceeds the limits of 

the  Clampmeter  may  damage  the  meter  and 

expose  the  operator  to  a  shock  hazard.   

Always  recognize  the  meter  voltage  limits  as 

stated on the front of the meter.

6

~

!

International Electrical Symbols

Dangerous Voltage

See Explanation in Manual 

AC Alternating Current.

Double Insulation (Protection Class II)

DC (Direct Current).

Both DC & AC

Not to be exposed to dripping or splashing environment.

Warning :-

- +

~

Deficiency of Built in Battery.

Continuity Test

Diode
Fuse

Ground

Hazardous

live conductor

HAND Barrier

o

F

A

Hz

~

V

W

DATA
PEAK

!

CAT III 600V

A

Hz

~

V

WARNING :- 

Typical meter applications are near   

exposed lethal voltages.  Use caution when taking 
measurements. Before the meter is connected to 
any circuit, review the safety information.  

Always keep hands 
behind the meter 
HAND Barrier.

7

Summary of Contents for 9999

Page 1: ...re current the same way as they measure voltage Remember you measure voltage across a circuit and current through a circuit When you use the current input your clamp meter becomes a low impedance circ...

Page 2: ...n Qty 1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 K Type Thermocouple 1 piece 4 Thermocouple Adaptor 1 piece In the event you find any Part missing or damaged please contact your dealer im...

Page 3: ...er F out side the o o o range of 18 to 28 C 65 F to 82 F Indoor use Altitude up to 2000m Safety Conformance All input are protected to EN61010 1 600V CAT III Pollution degree II EMC instrument unspeci...

Page 4: ...9999 W 0 1 1 Accuracy CAPACITANCE Range Resolution 0 to 999 9m F 0 1 m F Accuracy 5 rdg 10dgts Overload Protection 600V DC AC rms NOTE Supplied Thermocouple is suitable for o measurement upto 250 C f...

Page 5: ...pose a shock hazard 5 When using the probes keep your fingers behind the finger guards on the probes 6 Measuring voltage which exceeds the limits of the Clampmeter may damage the meter and expose the...

Page 6: ...cy Capacitance Temperature measurements and Continuity Diode Checks 8 FUNCTIONAL BUTTONS POWER ON THE METER Turn on the meter To select power on option Turn the rotaryswitch from zero position to any...

Page 7: ...s 2 Press the trigger to open transformer jaws and clamp on to one conductor only and turn on the motor 3 Read the INRUSH current directly from display Press and hold down the INRUSH button for more t...

Page 8: ...AX 999 9 VA m F W Hz 100 AUTO ZERO HOLD AC 0 25 50 75 AC P HOLD MAX MIN 11 m f m f Unit of Capacitance 12 A AC CURRENT MEASUREMENT 1 Set the range rotary switch to A 2 Press the trigger to open transf...

Page 9: ...III 600V DATA PEAK 600V MAX O Hz V A V O F W O C H B DC CURRENT MEASUREMENT Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz...

Page 10: ...V DATA PEAK 600V MAX O Hz V A V O F W O C H 16 1 Set the range rotary to position The is displayed 2 Turn off power to the circuit under test External voltage across the components causes invalid read...

Page 11: ...re Measurements K type Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz A CAT III 600V DATA PEAK 600V MAX O Hz V A V O F W O...

Page 12: ...the warranty period the same will be rectified by us free of charges provided the to and fro freight charges are borne by you This warranty extends only to the original buyer or end user customer of...

Page 13: ...MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE WHATSOEVER All transaction are subject to Mumbai Jurisdic...

Reviews: