Changing types of gas
20
Instructions for use - Gas hobs
7 Changing types of gas
WARNING
Danger caused by improper conversion to other types of gas
y
Have only qualified gas fitters convert the appliance to another type of gas in accordance with
local regulations.
y
The type of gas and the inlet pressure must comply with the appliance gas setting; see the
marking (back of the appliance).
y
Only use Küppersbusch injector sets (scope of delivery).
y
Before changing:
○
Close the gas stop valve.
○
Pull out the mains plug.
y
After changing:
○
Make changes permanently recognisable on the nameplate by sticking the labels for the
injector sets (scope of delivery) on the bottom of the appliance.
○
Check to ensure that there are no leaks on the gas connections.
○
Test the appliance for correct functioning.
○
The sealing must be renewed when the appliance has been converted to another type of
gas or when the gas pressure has been changed.
7.1
Injector specification
WARNING
Damage to health resulting from the use of unsuitable injectors
The use of injectors larger than those authorised for the gas/inlet pressure will damage the health
of the user (emission of CO) and of the appliance.
y
Only use Küppersbusch injector sets (scope of delivery). The
values in the following table are stamped on the injector heads!
Injector specification full flame injector / low setting injector
Type of gas
Individual burner
WOK burner
High-power
burner
Standard burner
Inside
Outside
Liquefied gas butane/propane
G30 (28 – 30/37 mbar)
98/25
65/25
50/23
72/45
Summary of Contents for GKS 3920.0