TECHNICAL SPECIFICATIONS

21

t

lf this appliance featuring magnetic door seals is
to replace an older appliance having a spring lock
(latch) on the door or lid, be sure to make that
spring lock unusable before you discard the old
appliance. This will prevent it from becoming a
death-trap for a child.

Positioning

The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc.
Best performance is obtained with ambient
temperature b18°C and +43°C (class T);
+18°C and +38°C (class ST); +16°C and +32°C
(class N); +10°C and +32°C (class SN).
The class of your appliance is shown on its rating
plate.

Attention!
It must be possible to disconnect the appliance

from the mains power supply; the plug must
therefore be easily accessible after installation.

For building-in and door reversibility refer to the
relevant instructions.

Electrical connection

Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.

Important

The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not
earthed. connect the appliance to a separate
earth in compliance with current regulations,
consulting a specialist technician.

The Manufacturer declines all responsibility if the
above safety precautions are not observed.

The technical data is indicated in the rating plate on the left side inside the appliance.

INSTALLATION

This appliance complies with the following
E.E.C. Directives:

- 87/308 EEC of 2/6/87 relative to radio interference

suppression;

- 73/23 EEC of 19.2.73 (Low Voltage Directive) and

subsequent modifications;

- 89/336 EEC of 3.5.89 (Electromagnetic

Compatibility Directive) and subsequent
modifications.

TAW1MERA

Door reversal (where necessary)

Warning!

When changing the side of the door opening,

the appliance may not be connected to the
mains. Remove plug from the mains
beforehand.

Summary of Contents for FTE 127-6

Page 1: ...emploi Belangrijk Beslist lezen en bewaren Importante È necessario leggere attentamente queste istruzioni e conservarle con cura Importante Leerlas imprescindiblemente y guardarlas Integrierte Einbau GefriergerŠte Integrated freezer Congélateur à intégrer Integreerbare diepvrieskasten Congelatori integrabili Congelador integrable Modell FTE 127 6 t F N I E p 14 24 25 37 38 50 51 62 63 74 Küppersbu...

Page 2: ... Freezing of fresh foods 18 Storage of frozen food 18 Thawing 18 Ice cube production 18 Tips 19 Tips for freezing 19 Tips for storage of frozen food 19 Maintenance 19 Defrosting 19 Periodic cleaning 20 Periods of non operation 20 Customer service and spare parts 20 Instructions for the Installer Technical specifications 21 Installation 21 Positioning 21 Electrical connection 21 Door reversibility ...

Page 3: ...rols or play with the product It is dangerous to alter the specifications or modify this product in any way Before any cleaning or maintenance work is carried out be sure to switch off and unplug the appliance This appliance is heavy Care should be taken when moving it Ice follies can cause frost burns if consumed straight from the appliance Take utmost care when handling your appliance so as not ...

Page 4: ...ainst a wall If the appliance has been transported horizontally it is possible that the oil contained in the compressor flows in the refrigerant circuit It is advisable to wait at least two hours before connecting the appliance to allow the oil to flow back in the compressor Environment Protection This appliance does not contain gasses which could damage the ozone layer in either its refrigerant c...

Page 5: ... the thermostat control knob clockwise beyond position O OFF The pilot light will light up to show that the appliance is on Freezer operation can be halted by turning knob to position O Temperature control Turn knob beyond the O position until its pointer coincides with the required setting To safely store frozen and deep frozen foods the inner temperature of the freezer must be at least 18 C or c...

Page 6: ...on up to 18 hours and the freezer is full otherwise it is recommended that the food should be used within a short time a temperature increase of the frozen food shortens its safe storage period Quick freezing Activate fast freeze by depressing the fast freeze switch The pilot lamp will then light up The SUPER function can be ended by pressing the button again The yellow light goes out Warning ligh...

Page 7: ...packs with the date on which freezing started so that you can keep a check on storage periods Tips for storage of commercially frozen food To get the best out of your freezer in the case of storage of commercially frozen food you should ensure that the products have been correctly stored by the retailer that there is only a very short time between when you purchase the products and when you put th...

Page 8: ...r clearing your appliance as it may get damaged Clean the inside with warm water and bicarbonate of soda Rinse and dry thoroughly To guarantee a safe operation of the fridge once a year remove the ventilation grille at the base and clean the air channels with a vacuum cleaner Periods of non operation When the appliance is not in use for long periods take the following precautions remove the plug f...

Page 9: ...wn on the serial number plate correspond to your domestic power supply Voltage can vary by 6 of the rated voltage For operation with different voltages a suitably sized auto transformer must be used Important The appliance must be earthed The power supply cable plug is provided with a contact for this purpose If the domestic power supply socket is not earthed connect the appliance to a separate ea...

Page 10: ...art involved with a normal hairdrier Dimensions of the recess PL880 Aligning the furniture housing 100 90 90 MAU2ME Instructions for totally built in appliances For safety reasons minimum ventilation must be as shown in Fig Attention keep ventilation openings clear of obstruction It is necessary that the niche is provided with a conduct of ventilation having the following dimensions Depth 50 mm Wi...

Page 11: ...ion steps are illustrated only when the door is hinged on the left please carry out the following installation steps on the opposite side as appropriate FAL1MERA 3 Cut joint cover fillets FAL3MERA PL09 5 Fit ventilation grill and push appliance into place 4 Apply joint cover fillets 1 Adjust height ...

Page 12: ... 7 Install screw head caps PL13 9 Apply door handle 8 Attach door panel PL12 10 Inserting the appliance door TE1MERA GAU4ME 11 Aligning the appliance door where necessary 6 Screw the appliance into place GF1MERA ...

Reviews: