H1-50-01-03
13
For internal use only
3.4
Pan sensor calibration after the power has been switched off
Select calibration
after switching on the power supply.
The pan sensors are calibrated.
3.5
Current program number
Version 01177
from 28.01.1997
Version 01277
Configurability installed for use in the EKE 604.2 or the EKE 804.2.
Note! The clamped connection schedule applies to the EKE 604.2 only!
In the case of the EKE 804.2 the relay functions for zones 1 and 3 have been
exchanged, i.e. on activating zone 1 K8 will switch and on activating zone 3 K4 will
switch (no function specification available).
Version 01377
from 17.09.1997
Diagnosis function installed: The relay and the display can be activated with a PC.
The operating cycle, the heating period meter and the operation time meter are
stored in the EEPROM. The data is added up in the EEPROM every time the hob is
switched off, i.e. in the event of a power cut, data hitherto collected in the processor
will be lost.
The following are also stored in the EEPROM:
•
PIC 73 + PIC 54 power-up resets
•
PIC 73 + PIC 54 watch-dog resets
•
PIC 73 + PIC 54 I2C bus error resets
•
Excessive temperature cut-off by means of PIC 54
•
Resets for faulty calibration data: PIC 73
•
Hob cut-off procedures in the event of impermissible sensors: PIC 73
Version 01477
from 7.10.1997
Software maintenance (no function specification available).
Version 01577
from 10.10.1997
Unintentional overwriting of the operating cycle meter for zone 1 eliminated.