![Küppersbusch EDG 6600.0 Service Manual Download Page 76](http://html1.mh-extra.com/html/kuppersbusch/edg-6600-0/edg-6600-0_service-manual_2010424076.webp)
76
H3-72-01
For internal use only
F5
Data backup
faulty (EEPROM)
1.
Calculator defect (component faulty, EMC influences, moisture,
dirt, etc.).
F7
Water temperature does not rise
sufficiently
(when the evaporator
heater is activated the water tempera-
ture does not rise sufficiently)
1.
Evaporator heater defect (excessive temperature cut-off device)
2.
Faulty wiring (plug connections, interruption, short circuit, loose
contact, etc.)
3.
Water temperature gauge does not react (plug of the water tem-
perature sensor dirty, etc.).
4.
Calculator defect (relay, etc.).
F8
Water resistance remains low
although water is being pumped off
(level pin remains conductive).
1.
Discharge pump transports insufficiently (tube blocked or
crushed)
2.
Level pin wiring short circuit
3.
Foam in the evaporator casing (unsuitable descaling agent)
4.
Calculator defect, possibly as a result of moisture.
F9
Air temperature does not rise suffi-
ciently
, although the evaporator
heater has been activated.
1.
Coil of the inlet/outgoing air flap has been interrupted
2.
Inlet/outgoing air flap is stuck, has come out or the steam hole is
blocked
3.
Inlet air plug porous, defect, dropped off, etc.
4.
Oven leaks (loss of steam, doors not properly closed?)
5.
Evaporator heater defect (excessive temperature cut-off device)
6.
Air temperature sensor does not take accurate measurings.
Sensor hole blocked
7.
Too much cold food has been put into the oven (for steaming a
max. 2 kg of food is permissible)
8.
Calculator defect, possibly as a result of moisture.
U 1
No voltage or too little voltage
measurable between the terminal con-
ductor and the earthed conductor
1.
Earthed conductor not connected
2.
Faulty installation in the building (loose contact, interruption,
etc.)
U 2
Excessive differential voltage
be-
tween the earthed conductor and the
neutral conductor.
1.
Terminal conductor (P1) and neutral conductor (N) have been
exchanged.
2.
Faulty installation in the building (loose contact, interruption,
etc.)
U 3
Under-voltage on the terminal con-
ductor
(P1) <147...198V
1.
Voltage fluctuation
2.
Faulty installation in the building (loose contact, interruption,
etc.)
Ü:..
Excessive voltage on the terminal
conductor
(P1) >244..313V
1.
Voltage fluctuation
2.
Faulty installation in the building (loose contact, interruption,
etc.)
No signal
Heater for hot air does not heat up.
1.
There is no supply on the L2 terminal of the calculator
(instructions for installation observed?).
2.
Hot-air heater faulty (plug connections, interruption, short
circuit, loose contact).
3.
Faulty wiring (interruption, short-circuit, loose contact, etc.).
4.
Evaporator heater defect (excessive temperature cut-off device)
5.
Automatic cut-off by F2 thermostat (the appliance will need to
be replaced if the are signs of overheating on the muffle)
No
message
At times unusual illegible signs on
the text display
1.
VFD module is damp as a result of steam getting in behind the
panel
2.
VFD module defect or computer possible defect.
dEno
Demonstration mode is activated
(message only appears after a power
cut)
The mode intended for exhibition purposes. No heaters are
switched on and no error messages are given.
Summary of Contents for EDG 6600.0
Page 1: ...p l bb_a SSMMKM bad SSMMKM bhad SUMMKM bad SSMMKN bhad SUMMKN bhad SUMMKO bhad SUMMKMJTR...
Page 29: ...H3 72 01 29 For internal use only 5 3 Water system Ignition solenoid Water tank 1 25 litres...
Page 51: ...H3 72 01 51 For internal use only 7 1 3 Sequence diagram Steaming EEBD 6600 0...
Page 53: ...H3 72 01 53 For internal use only Sequence diagram Regenerating EDG EKDG...
Page 54: ...54 H3 72 01 For internal use only 7 2 2 Sequence diagram Regenerating EEBD 6600 0...
Page 57: ...H3 72 01 57 For internal use only Sequence diagram Baking like professionals EDG EKDG...
Page 58: ...58 H3 72 01 For internal use only 7 3 2 Sequence diagram Baking like professionals EEBD 6600 0...
Page 97: ...H3 72 01 97 For internal use only 11 3 Flow chart Descaling programme EEBD 6600 0...