Using the fan
19
GB
Disable automatic after-run
1. Turning on the control via the ON/OFF key on the fan
.
2. Press the ON/OFF key on the fan for approximately 3
seconds
until
is displayed. The automatic fan is
permanently disabled.
Enable automatic fan run
1. Turning on the control via the ON/OFF key on the fan
.
2. Press the ON/OFF key on the fan for approximately
3 seconds
until
is displayed. The automatic fan
run is permanently activated.
4.3.3 Notes on the after run time
The fan motor should continue operating for another 10-20
minutes every time the hob has been used for cooking.
When the fan is switched o
ff
after having been in operati-
on for at least 15 minutes, an automatic time lag at a low
setting will follow for around 15 minutes.
This guarantees optimal functioning and the removal of
remaining cooking steam.
When using a recirculating air
fi
lter, please always allow for
a stop delay time of 10 - 60 minutes in order to optimally
remove cooking odours.
When the fan is switched on again, in rare cases the odour
molecules present in the
fi
lter may be combined with
steam so that they are detected again. These remaining
odours will disappear when the fan continues to operate.
Important
When the convection air mode is in operation, ventilation
must be su
ffi
cient in order for the air humidity to be remo-
ved.
4.3.4 Display: Clean the grease
fi
lters
After 10 hours of operation the display
for
fi
lter clea-
ning appears. The grease
fi
lter must be cleaned, otherwise
there is a risk of
fi
re.
To continue to use the ventilation, con
fi
rm the display
with the Minus key .
If the grease
fi
lter has been cleaned, you can delete the
display
by pressing the Minus key and the ON/OFF
key on the fan at the
same time for at least 3 seconds.
The counter for the display starts again at 0 hours.
4.3.5 Display: Replace the charcoal
fi
lter
After 150 hours of operation the display for Carbon Clea-
ning appears
. The charcoal
fi
lter needs to be repla-
ced.
To continue to use the ventilation, con
fi
rm the display
using the Plus key to .
If the carbon
fi
lter has been replaced, you can delete the
display
by pressing the Plus key and the ON/OFF
key on the fan at the
same time for at least 3 seconds.
The counter for the display starts again at 0 hours.
4.3.6 Turn o
ff
the carbon
fi
lter operating hours coun-
ter during the operation of the air exhaust
During the operation of the air exhaust, the operating
hours counter for the carbon
fi
lter must be turned o
ff
.
To do this, the control panel must
fi
rst be turned on using
the ON/OFF key of the fan
and there may not be any
messages displayed.
Then simultaneously press the Plus key and the ON/
OFF key of the fan
for 3 seconds.
The display will show
(carbon o
ff
) and the operating
hours counter for the charcoal
fi
lter is turned o
ff
.
To turn the operating hours counter back on, repeat the
operation.
The display will show
(carbon o
ff
) and the operating
hours counter for the charcoal
fi
lter is turned o
ff
.
Summary of Contents for VarioLine K Series