Operation
37
GB
4.22 Locking
The lock can be used to lock key operation and cooking
level settings. Only the ON/OFF key can be used to switch
the hob off .
Activating the lock
1. Press the lock key . The lock key will light up brightly.
The lock will now be activated.
Switching off the lock
2. Press the lock key . The lock key will light up with a
dimmed light.
The lock is now switched off .
Notes
An activated lock will remain activated even if the hob is
switched off . It must therefore be de-activated when cook-
ing is re-commenced.
The activated lock will be cancelled, i.e. de-activated, in
the event of a power failure and when the ON/OFF key is
used for switching off .
4.23 Power boost
The power boost setting makes additional power available
for induction cooking zones. A large quantity of water can
be brought to the boil very quickly.
1. Switch on the hob. Use the power setting display (as a
key) to select a cooking zone. The stand-by dot of the
cooking zone selected will light up.
2. Press the
sensor fi eld on the far right. The
power boost setting will be activated.
3. After 10 minutes the power boost setting will switch off
automatically. The will go off and the power level will
switch down to 9.
Please note
Press the sensor fi eld to prematurely de-activate the pow-
er boost.
4.24 Power management
For technical reasons two cooking zones always comprise
a module and have a maximum power level.
If this power range is exceeded when a higher power
setting level or the power boost function is switched on the
power management system will reduce the power setting
of the corresponding cooking zone of the module.
The display for this cooking zone will initially blink, after
which the highest-possible power setting will be consis-
tently displayed.
10 min.
Modules (power management)