1

150/ 120 mm reduction.

Anti-recoil valve.

2

Supports for tubecover.

2

Supports hall.

6

Wall plugs (Ø8 x 40).

6

Long bolts (Ø5 x 45).

4

Wall plugs (Ø6 x 30).

4

Long bolts (Ø4 x 30).

2

Washers (Ø6.4 x Ø18).

2

Washers (Ø6.4 x Ø12).

2

Screws (Ø3.9 x 19).

4

Screws M4 x 12.

2

Clips.

Fig. 1 (Page 39)
On installing the kitchen hood make sure
that  the  Safety  Instructions  set  out  on
page 10 are complied with.

To obtain optimum performance, the external
duct must not be more than FOUR METRES
LONG, have no more than two 90° angles and
its diameter must be at least Ø120.

1) Trace and drill the points for fitting the wall
plugs onto the wall (P) (Ø8 x 40) and (J) (Ø6
x 30). See figure 1.
2)  Attach  the  Supports  (O)  to  the  wall  using
the long bolts (Q) (Ø5 x 45) and the support
(H)  with  the  long  bolts  (I)  (Ø4  x  30),  as  in
figure 1.
3) Fit the body of the hood to the support (O)
and level the hood using the long bolts (L) (M4
x 12).
4) Trace the location of the wall plugs (R) (Ø8
x 40), through the inside of the kitchen hood.
5) Take the kitchen hood off.
6) Drill into the wall and fit the wall plugs (R)
(Ø8 x 40).
7) Hang the kitchen hood; tighten the screws
(M) (M4 x 12) with the washers (A3) (Ø6.4 x
Ø12) and the long bolts (S) (Ø5 x 45) with the

washers (T) (Ø6.4 x Ø18).
8) Mount the tubecovers, attaching the lower
one  to  the  support  (H)  as  per  the  detail  in
figure  1.  Lift  the  upper  tubecover  up  to  the
desired height and mark its shape on the wall.
Remove the tubecovers.
9)  Fit the clips (F) to the support (C). 
10) Centre the support (C) around the shape
marked; trace and drill the fixing points for the
wall  plugs  (E)  (Ø6  x  30).  Attach  the  support
(C) with the long bolts (D) (Ø4 x 30).
11)  Fit  the  part  (A)  if  the  inner  tube  (not
supplied) is Ø150 or (A) + (B) if it is Ø120.
12)  Attach  the  inner  tube  with  a  clamp  (not
supplied) to (A) or (B) as the case may be.
13) Once the inner tube has been fitted, fit the
lower  tubecover  around  the  extractor  fan
outlet and attach the upper tubecover with the
screws (G) (Ø3.9 x 19).

When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air  by  recycling  it  through  active  charcoal
filters.
The active charcoal filters have an active life
of between three to six  months, depending on
the individual  conditions of use. These filters
cannot  be  washed  nor  regenerated.  They
must be replaced once their useful life comes
to an end.

Fig. 2 (Page 39)

1) Remove the metal filters.
2)  Put  the  charcoal  filters  (A)  into  the  lateral
draught section (B) of the motor.
3) Fit the metal filters.
4) Remove the tubecovers (H). Fit the support
(J)  in  the  diffuser  (C).  Mount  the  connector
Ø150 (L) in the diffuser base.
5)  Use  the  wall  plugs  and  the  previously
installed  upper  tubecover's  support  (I)  long
bolts (D) (Ø4 x 30) to fix diffuser into the wall
(C). 
6)  Connect  the  connector  base  (L)  to  the
motor  exit  via  the  inner  tube  (not  supplied).
Use clamps (Not supplied). Fit the tubecovers
(H) again. 

Installation

EN

G

 

Accesories supplied

13

Active charcoal filters  (Optional)