Fixing the frame
• Loosen the two screws fastening the lower chimney and remove this
from the lower frame.
• Loosen the two screws fastening the upper chimney and remove this
from the upper frame.
If you wish to adjust the height of the frame, proceed as follows:
• Unfasten the metric screws joining the two columns, located at the sides
of the frame.
• Adjust the frame to the height required, then refit all the screws removed
as above.
• Insert the upper chimney stack from above, and leave it running free on
the frame.
• Lift up the frame, fit the frame slots onto the screws up to the slot end
positions.
• Tighten the two screws and fasten the other two screws provided with the
hood.
Before tightening the screws completely it is possible to adjust the frame by
turning it. Make sure that the screws do not come out of their seats in the
slotted holes.
• The frame mountings must be secure to withstand the weight of the hood
and any stresses caused by the occasional side thrust applied to the de-
vice.
On completion, check that the base is stable, even if the frame is subject-
ed to bending.
• In all cases where the ceiling is not strong enough at the suspension point,
the installer must provide strengthening using suitable plates and backing
pieces anchored to the structurally sound parts.
2
2
1
1
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using
either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to
the installer.
To install a ø 150 pipe
• To install the dumper
10
• Fix the pipe in position using sufficient pipe clamps (not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection, insert the reducer flange
9
on the dumper
10
.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Remove any activated charcoal filters.
ø 120
ø 150
10
10
9
Summary of Contents for IKD12780.0E
Page 8: ...DE 8 8 Platzbedarf 600...
Page 18: ...EN 1 18 Dimensions 600...
Page 28: ...FR 2 28 Encombrement 600...
Page 38: ...NL 3 38 Buitenafmetingen 600...
Page 48: ...IT 4 48 Ingombro 600...
Page 58: ...ES 5 58 Dimensiones 600...
Page 68: ...PT 6 68 Dimens es 600...
Page 74: ...GR 7 74 650 mm 120 mm 0 04 mbar 2...
Page 75: ...GR 7 75 3 mm 8...
Page 76: ...GR 7 76 2 4...
Page 78: ...GR 7 78 600...
Page 79: ...GR 7 79 21 20 mm 10 mm 11 7 mm 10 mm 4 5 mm 20 mm 12h 12g 22 23...
Page 80: ...GR 8 80 2 2 1 1 150 120mm 10 120mm 9 10 120 150 10 10 9...
Page 82: ...GR 8 82 T1 T2 T3 T4 L T1 T2 T1 T2 T3 T1 T3 2 30 T1 T2 T3 T4 T4 T1 T4 2 6 L...
Page 83: ...GR 8 83 2 4 LED 1M EN 60825 1 1994 A1 2002 A2 2001 439nm 7 W...
Page 84: ...RU 8 84 650 I 120 0 04 2...
Page 85: ...RU 8 85 3 8...
Page 86: ...RU 8 86 2 4...
Page 88: ...RU 8 88 600...
Page 89: ...RU 8 89 21 20 10 11 7 10 4 5 20 12h 12g 22 23...
Page 90: ...RU 9 90 2 2 1 1 150 120 150 150 10 120 120 9 150 10 120 150 10 10 9...
Page 92: ...RU 9 92 T1 T2 T3 T4 L T1 T2 T1 T2 T3 T1 T3 2 30 T1 T2 T3 T4 T4 T1 T4 2 6 L...
Page 93: ...RU 9 93 2 4 1M EN 60825 1 1994 A1 2002 A2 2001 439nm 7...
Page 94: ......