en
28
Installation
The dishwasher must be connected by
a qualified technician to ensure correct
operation. The specifications for supply,
drainage and connected load must fulfil
the required criteria as stated in the
following paragraphs or in the installation
instructions.
Install the appliance in the following
sequence:
– Check the delivery
– Install the appliance
– Connect the waste water
– Connect the fresh water
– Connect the power supply
Delivery
Your dishwasher was checked at the
factory to ensure that it was in perfect
working order. This may have left some
small water stains in the dishwasher.
These will disappear after the first rinse
cycle.
Installation
The required installation dimensions can
be found in the installation instructions.
Using the height-adjustable feet, adjust the
appliance until it is level. Ensure that the
appliance is standing firmly.
Waste water connection
See the installation instructions for the
required connection steps. If required,
attach a siphon with drainage spigot.
Using the enclosed parts, connect the
waste water hose to the drainage spigot
of the siphon.
Ensure that the drainage hose is not
kinked, crushed or twisted (ensure that
there is no sealing cover which prevents
the waster water from flowing away!).
Fresh water connection
Using the enclosed parts, connect the
fresh water connection to the tap
according to the installation instructions.
Ensure that the fresh water connection is
not kinked, crushed or twisted.
When replacing the appliance, always
connect a new water supply hose to the
water supply. The old supply hose must
not be re-used.
Water pressure:
Minimum 0,05 MPa (0,5 bar) – maximum
1 MPa (10 bar).
If the water pressure is higher, install a
pressure reducing valve.
Flow rate:
Minimum of 10 litres per minute.
Water temperature:
We recommend that you use cold water.
If you do use hot water, the temperature
should not exceed 60
°
C.
Electrical connection
Connect the appliance only to 230 V
alternating current via a correctly installed
socket with protective conductor.
See rating plate for required fusing
31
.
The socket must be attached near the
dishwasher and be freely accessible.
The connection may be modified by an
electrician only.
Use only a residual-current-operated
circuit-breaker which features the
symbol. Only this circuit breaker
guarantees compliance with the currently
valid regulations.