Service Manual GCM 642.0 ME/GES 642.0
9
For internal use only
3.2 General notes on the installation
a)
Make the worktop and control panel recesses in accordance with the
specified dimensions.
b)
Secure the sheet panelling on all four sides in the worktop recess with the
enclosed nails (see Fig.).
The angled part of the shielding sheets rests on the worktop. The notch on
the angled side of the sheets must coincide with the centre of the worktop
recess.
c)
In order to fasten the shielding sheets in granite worktops glue them into the
recess by means of heat-resistant silicon adhesive, e. g. Pactan.
d)
Secure support angles on the left and right in the switch panel recess with
the enclosed screws in such a way that there is a distance of 502 mm
between the notch points (see Fig.).
502
Support angle
Notch point