  The electrical circuit must be separated from the network by adapted devices, for example: 

circuit breakers, fuses or contactors. 

  If  the  appliance  is  not  fitted  with  an  accessible  plug,  disconnecting  means  must  be 

incorporated in the fixed installation, in accordance with the installation regulations. 

  The inlet hose must be positioned so that it does not touch any of the hot parts of the hob 

or even. 

Caution! 

This appliance must only be connected to a network 230 V~ 50/60 Hz. 
Always connect the earth wire. 
Respect the connection diagram. 
The connection box is located underneath at the back of the hob casing. To open the cover use a 
medium screwdriver. Place it in the slits and open the cover. 

 

* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990 

Connection of the hob 

For the various kinds of connection, use the brass bridges which are in the box next the terminal 

Monophase  230V~1P+N 

Put the 1

st

 bridge between terminal 1 and 2, the 2

nd

 between 3 and 4. 

Attach the earth to the terminate “earth”, the neutral N to terminal 3 or 4, the Phase L to one of 
the terminals 1 or 2. 

Biphase 

400V~2P+N 

Put a bridge between terminal 3 and 4. 
Attach  the  earth  to  the  terminate  “earth”,  the  neutral  N  to  terminal  3  or  4,  the  Phase  L1  to  the 
terminals 1 and the Phase L2 to the terminal 2. 

 
 
Caution! 

Ensure that the cables are correctly inserted and tightly screwed down. 

 
 
 
 
 

Mains 

Connection 

Cable diameter 

Cable 

Protection calibre 

230V~  50/60Hz 

1 Phase + N 

3 x 2,5 mm² 

H 05 VV - F 

H 05 RR - F 

25 A * 

400V~  50/60Hz 

2  N 

4 x 1.5 mm² 

H 05 VV - F 

H 05 RR - F 

16 A * 

We cannot be held responsible for any incident resulting from incorrect connection or 

which could arise from the use of an appliance which has not been earthed or has been 

equipped with a faulty earth connection. 

Summary of Contents for EKI8940.1BCF

Page 1: ...BEDIENUNGSANWEISUNG mit Montageanweisungen Instructions for use and installation Instructions d utilisation et d installation EKIF8940 1 EKI8940 1ED EKI8940 1F EKI8940 1PWF EKI8940 1BCF...

Page 2: ...APPLIANCE 23 DISPLAY 23 VENTILATION 24 STARTING UP AND APPLIANCE MANAGEMENT 24 BEFORE THE FIRST USE 24 INDUCTION PRINCIPLE 24 SENSITIVE TOUCH 24 SLIDER ZONE TO SET POWER AND TIMER VALUES 25 STARTING...

Page 3: ...es off after using Keep an eye on the cooking using grease or oils that may quickly ignite Be careful not to burn yourself while or after using the appliance Make sure no cable of any fixed or moving...

Page 4: ...er put any inflammable object ex sprays into the drawer situated under the vitroceramic hob The eventual cutlery drawers must be resistant to heat Precautions in case of appliance failure If a defect...

Page 5: ...cription 0 Zero The heating zone is activated 1 9 Power level Selection of the cooking level U No pan detection No pan or inadequate pan A Heat accelerator Automatic cooking E Error message Electronic...

Page 6: ...f the pan The result is a heating up of the pan located on the heating zone Of course the pan has to be suitable All ferromagnetic pans are recommended please verify it thanks a little magnet cast iro...

Page 7: ...isplay To set slide on the SLIDER 1 to 9 adjust the power to the right or to the left To stop slide to 0 on SLIDER 0 or H If no action is made within 10 second the electronics return to the waiting po...

Page 8: ...ion Control panel Display Start up the Booster Press key Booster key P blinks then press on the SLIDER of P the desired zone Stop the Booster Slide on the SLIDER P to 0 Start up Stop the double booste...

Page 9: ...ks Stop the time Slide on the SLIDER Decrease the time at 00 If several timers are running in parallel repeat the process Egg timer function Egg timer is an independent function It stops as soon as a...

Page 10: ...er to the pre selected level Start up Action Control panel Display Power level selection slide on the SLIDER to 7 7 is blinking with A for example 7 and hold 3s Switching off the automatic cooking Act...

Page 11: ...g zone related timers Automatic cooking Keep warm function The recall procedure is following Press the key Then press Stop key before the light stops blinking The previous settings are again active Ke...

Page 12: ...accidentally activating or interfering with the settings of the cooking zones for instance when cleaning the control panel can be locked with exception of the On Off key Action Control panel Display L...

Page 13: ...an placed on an induction heating zone set at level 9 This water must heat in a few seconds A magnet sticks to the bottom of the pan Certain pans can make noise when they are placed on an induction co...

Page 14: ...ities of water MAINTENANCE AND CLEANING Switch off the appliance before cleaning Do not clean the hob if the glass is too hot because they is a risk of burning Remove light marks with a damp cloth wit...

Page 15: ...commune that is adapted to the recycling of the household appliances 33 WHAT TO DO IN CASE OF A PROBLEM e cooking zone doesn t start up The hob is badly connected on the electrical network off The lo...

Page 16: ...o stick the gasket The gasket supplied with the hob prevents the intrusion of liquids into the cabinet below Its installation has to be done carefully as described below Fitting installing Cut out siz...

Page 17: ...cations of the hood manufacturer In case of absence of instructions respect a distance minimum of 760 mm The connection cord should not be subjected after building in to any mechanical constraint for...

Page 18: ...ion of the hob For the various kinds of connection use the brass bridges which are in the box next the terminal Monophase 230V 1P N Put the 1st bridge between terminal 1 and 2 the 2nd between 3 and 4...

Page 19: ...16743 0...

Reviews: