Service Manual EDG 650.0
21
For internal use only
Reed switch card, display
or main card not working
Water level
reading maximum
Press the
PLUS button
Press the
PLUS button
P3 will be displayed
P2 will be displayed
Energy consumption
1800W<P<2000W
Press the
PLUS button
Open door
Replace the reservoir
P1 will be displayed
Probe not working or
not connected, main
card not working
Main elements not working
or not connected,
Main card not working
Tangent not working or
not connected, main
card not working
Consumption
≈
20 W
Probe Test
Total Consumption
Tangent Test
YES
YES
NO
NO
NO
YES
Reed Switch Test
Test