6
Technical passporT
english
electric hob
letter l (live) = cable brown colour;
letter N (Neutral) = cable blue
colour;
Symbol
(earth) = cable gren-
yellow colour.
Our hobs can also operate with
three phase power carry out the relative
respondences. Connect the cables
acording to the scheme of Fig.13, making
sure to respect the undermentioned
respondences:
leter l1 (live) = cable brown colour;
leter l2 (live) = cable black colour;
leter l3 (live) = cable black colour;
leter N (Neutral) = cable blue colour;
Symbol
(earth) = cable green-
yellow colour.
B
The input cable has to be
located so that never reach the over
temperature of 100°C.
B
Please do not use in the
connection any reduction, adaptation
that may provoke a false contact with
following dangerous overheatings.
B
The outlet must be acresible
after the built-in.