KUNBUS Ethernet Test Access Point TAP-2100

3  Operation

3.1 Installation

1. 

After taking the delivery, please check whether all items listed in Chapter  
„1.1. Scope of delivery“are present. 

2. 

Connect the device using the included power cable

3.  

The POWER LED lights

4. 

 Laden Sie sich die Netzwerkanalyse-Software „Wireshark“ auf den PC 
und installieren Sie sie. Sie 

fi

 nden Wireshark auf www.wireshark.org.

4.  Download the Wireshark plugin DLL from the KUNBUS website, and 

copy it to the Wireshark plugin directory(e. g.: C:\Programme\Wireshark\
plugins\1.10.2). 

•  32-Bit-Version: tap32_xxxx.dll (Wireshark-Plugin WIN32)

•  64-Bit-Version: tap64_xxxx.dll (Wireshark-Plugin WIN64)

 

 

 

xxxx stands for the version of Wireshark.(z.B. 1.10.2)

5.  

Connect the TAP-2100 with the RJ45 cable to a Gigabyte Ethernet 
interface of the PC.If the connection between PC and TAP is successful, 
the X0 link LED lights up.

6. 

Plug the line to be tested into the probe ports. The two ports ‘Port 1’ and 
‘Port 2’ are connected directly. Therefore a connection is also possible 
when the TAP is turned off. If the TAP is on and the a connection is 
established, the link LEDs will be on. Between the two Ports the TX 
and RX pins are exchanged. If a 1:1 cable must be monitored it must 
be connected to the TAP and the TAP must be connected to the other 
device using a crossover cable. If the devices are Auto-MDI-X capable 
no attention must be paid on the kind of cable.

7.  Start Wireshark on the PC. The plug-in ‚TAP‘ must be 

‚enabled‘ in the menu  „Edit > Preferences > Protocols > TAP“.

8. 

In Wireshark, start data capture on the Gigabyte Ethernet interface used.

9. 

Now the data can be analyzed using Wireshark.

Summary of Contents for TAP-2100

Page 1: ...Ethernet Test Access Point KUNBUS TAP 2100 Brief Instruction...

Page 2: ...to the extent specified in General Terms and Conditions www kunbus de agb html The contents published in this user manual are protected by copyright Any reproduction or use for the in house requiremen...

Page 3: ...prevent damage to property and personal injuries 6 Limitation of Liability 7 Introduction 8 Scope of delivery 8 Areas of use 8 Technical data 9 General data 9 Operation 10 Installation 10 Operation wi...

Page 4: ...KUNBUS GmbH 4 KUNBUS Ethernet Test Access Point TAP 2100...

Page 5: ...Measuring and analyzing electrical functions and systems Safety and health at work Assembly and connection of electrical equipment Locally applicable rules and regulations for occupational safety 1 2...

Page 6: ...ion Only use the TAP 2110 with the supply voltage of 24V DC 5 Using other voltages result in damages or faults Caution Only use the the specified signaling voltage Operation with a signaling voltage o...

Page 7: ...tion of Liability Warranty and liability claims will lapse if the product has been used incorrectly damage is due to non observance of the operating manual damage is caused by inadequately qualified p...

Page 8: ...ernet interface Network monitors read and analyze the tapped packet data such as the freely available Wireshark 2 1 Scope of delivery Storage case TAP 2100 Plastic cover Cable for power supply Euro Ad...

Page 9: ...lex Zero delay 0 s Resolution time stamp 1 ns Diagnostics 3 LEDs Unfiltered forwarding of CRC errors 2 4 General data Supply voltage 24 V DC 20 or 230 V AC plug power supply Weight about 150 g Dimensi...

Page 10: ...Connect the TAP 2100 with the RJ45 cable to a Gigabyte Ethernet interface of the PC If the connection between PC and TAP is successful the X0 link LED lights up 6 Plug the line to be tested into the...

Page 11: ...s provided that can easily be understood from the user side This way there is an opportunity to examine individually captured data packets or to sort by specific contents In addition to extracting for...

Page 12: ...reshark dialog can be accessed via the menu selection Capture Interfaces The dialog in turn shows with all the corresponding IP addresses the respectively recognized network interfaces Furthermore it...

Page 13: ...nder columns Enter for example tap port as the field name As soon as tap has been entered all possible values are displayed A description is provided below With Add a column can be added Using the mou...

Page 14: ...at both devices switch over to MDIX and the display of A B is swapped The same applies to C D CRC Error The received packet has a faulty test total Alignment Error The packet is faulty Timestamp The p...

Page 15: ...ets If a packet is already more than 1480 bytes long the packet on the output port X0 will exceed the maximal allowed length of the Ethernet standard and the packet will be discarded by the network ad...

Page 16: ...n problems with the TAP 2110 Revision SW0030R02 up to 17th September 2015 The very first Ethernet frame sent on one of the lines observed by the TAP 2110 after a restart of the device i e TAP 2110 run...

Reviews: