12 |
EN
The parameter settings
Setting the cutting mode
Press the mode button to select the mode suitable
cutting mode.
Standard cutting
- used for normal cutting of solid ma
-
terials.
Cutting of perforated material
- used for dividing ma
-
terials where cutting is interrupted during cutting cycle
(gap between materials, perforated sheets, grids, etc.)
Mode switching button
Perforated material
cutting mode
Air test
Standard cutting mode
Setting the cutting current
Rotating the control N-coder is increasing or lowering of
the cutting current of the machine.
N-coder
Setting the required
current
Setting the AIR TEST function
Press the mode switch button one by one to select the
desired function. Then press the control button on the
torch to check the correct air pressure setting. The cu
-
rrent air pressure will be shown on manometer.
Mode switching button
Air test
Explanation of terms
Automatic torch check
If a problem with the torch is detected, the warning
light comes on and the cutting power is blocked. A fla
-
shing light indicates a nozzle installation error. A steady
light indicates, for example, damage or missing torch
consumables.
Automatic air pressure control
Switch the mode switch sequentially to set the Air Test
function to open the valve and air flow. This function
is used to set and test the correct air cutting pressure.
Fault signaling
Activation occurs when the supply voltage is too high
voltage or current, overheating and machine malfunc
-
tions. If signaling is activated, cutting power is blocked.
Air pressure adjustment
Correct air pressure adjustment has a major effect on
the result cutting. If the pressure is set incorrectly, it is
not possible to achieve a quality cut due to insufficient
performance, the plasma torch, the power source may
be damaged and consumables may be worn excessive
-
ly. The optimum air pressure is 0.45 - 0.5 MPa (65-75
Psi) and min. flow 120 l / min. The correct air pressure
must always be set with the plasma torch connected.
Use the controller‘s n-encoder to set the correct air pre
-
ssure. To activate the n-coder, pull upwards to release
the anti-twist lock. Rotate left or right to set the correct
pressure. After adjustment, push the n-coder down to
lock the position.
Air filter / condensation vessel
The correct cut quality is also influenced by the clean
-
liness and humidity of the air. Moist and polluted air
affects the quality of the cut and quality results cannot
be achieved. The plasma cutting machine is supplied
with a basic filter and a condensation vessel. If exce
-
ssive condensation is present in the condensation ve
-
ssel, the compressed air supply must be checked and, if