Putting into service
Silo unloader - Straw spreader - Mixer - Distributor
ALTOR 7560
47
Electrical connections
Lighting
Connect to the standardized 7-pin socket located at the
back of the tractor.
Control and Weighing Unit Power Supply
On tractors equipped with a 3 terminal female connector
in accordance with the standard DIN 9680A, connect the
control and weighing unit directly.
For other tractors, a harness to be connected directly to
the battery is delivered with the machine.
The wiring harness is fitted with a 15 Amp ATO type
fuse.
To use the machine with another tractor, a
second tractor-side power harness can be
ordered under p/n A7040170.
Control box
Harness on tractor side
Machine
Fuse type ATO
Fuse
Harness references
ALTOR 7560 Standard
15 A 83233017
A7040069
ALTOR 7560 Adjustable chute
20 A 83233018
A7040069
ALTOR 7560 Mixer hopper
15 A 83233017
30 A 83233020
A7040170
ALTOR 7560 Mixer
Swivel chute
20 A 83233018
30 A 83233020
A7040170