Operation Manual - I
Ϯ
Make sure all parts of the product are clean and rustless.
Ϯ
No leakage occurs while the product is not operated.
Ϯʳ
No leakage occurs (either at low pressures or at high pressures)
while the product is tested without cables.
Ϯʳ
Hydraulic pressure should be able to reach 700 bar / 10,000 psi
while tested without cables.
Ϯʳ
Operations without dies in place are strictly prohibited.
Ϯʳ
Check the cleanness of the product before use.
Ϯʳ
Make sure no loose parts exist before use.
Ϯʳ
Always use dies which fit the specifications. No overloaded com-
pression is allowed.
Ϯʳ
Stop operating immediately in case of any abnormalities.
ΰ
Please refer to "Page 8 : Trouble-Shooting"
α
1. Compression of lugs cannot be implemented.
2. Moving handle is stuck or is unable to rotate to release the pressure.
3. Dies can not be set in place or can not be removed.
4. The piston is stuck or is unable to retract after operation.
Ϯʳ
Clean the product and dies after use. Apply rust preventive oil to the
product and dies before putting back to the carrying case.
Page: 5
KuDos Industrial Inc. U.S.A.