COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S75
9Y1200192CRS0615US0
Name
Intake air temperature error
ISO 14229
P-Code
P0112
P0113
J1939-73
SPN
172
172
FMI
4
3
DTC Name
Intake air temperature error: Low
Intake air temperature error: High
Management Unit
for Detected Part
THAL
THAH
Detection item
• Ground short circuit of sensor / harness
• Open circuit or +B short circuit of sensor
/ harness
DTC Set
Preconditions
• Battery voltage is normal
• Battery voltage is normal
DTC set parameter
• Voltage of intake air temperature sensor
is 0.05 V or less
• Voltage of intake air temperature sensor
is 4.9 V or above
Time to action or
number of error
detection
• 2.8 sec. or more
• 2.8 sec. or more
System Action
• At start-up =
−
20 °C
(
−
4 °F) [default value]
• Under other conditions = 40 °C (104 °F)
[Default value]
• At start-up =
−
20 °C
(
−
4 °F) [default value]
• Under other conditions = 40 °C (104 °F)
[Default value]
Behaviour During
Malfunction
• Amount of white smoke increases at low
temperatures
• Amount of white smoke increases at low
temperatures
Engine Warning
Light
• ON
• ON
Recovery from
error
• Diagnostic counter = zero
• Diagnostic counter = zero
KiSC issued 05, 2012 A