CONNECTING THE LOAD
CONNECTING THE LOAD
MOKUJIYOU
B
Connection Notes
To avoid personal injury:
A
Before the generator can be
connected to a building’s electrical
system, a licensed electrician must
install an isolation (transfer) switch
in the building’s main fuse box. The
switch is the connection point for
generator power and allows
selection of generator or main line
power to the building. This will
prevent the generator from charging
the main power line (backfeeding)
when the main power supply has
failed or has been turned off for line
repair. Backfeeding can electrocute
or injure line maintenance personnel.
Also, generator and building
electrical system damage can occur
when normal operating power
returns if unit is used without an
isolation switch.
1. Avoid connecting the generator to commercial power
outlet.
2. Avoid connecting the generator in parallel with any
other generator.
B
Connecting the Load
To avoid personal injury:
A
Connect or disconnect the load to
the AC receptacle only when the
engine is stopped.
1. Turn OFF the circuit breakers on the control panel.
2. Connect the load to the A.C. output terminals.
3. Finally be sure to close the cover and tighten up the
lock screws.
(1) Circuit breaker
(1) Terminals (output)