75
TROUBLESHOOTING
BATTERY TROUBLESHOOTING
If you have any questions, consult your local KUBOTA Dealer.
Trouble
Cause
Countermeasure
Preventive measure
Starter does not function.
A
Battery overused until
lights are dim.
A
Charge battery
sufficiently.
A
Charge the battery properly.
A
Battery has not been
recharged.
A
Poor terminal
connection.
A
Clean the terminal
and tighten securely.
A
Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
A
Battery life expired.
A
Renew battery.
From beginning starter
does not function, and
lights soon become dim.
A
Insufficient charging.
A
Charge battery
sufficiently.
A
Battery must be serviced
properly before initial use.
When viewed from top,
the top of plates look
whitish.
A
Battery was used with
an insufficient amount
of electrolyte.
A
Add distilled water
and charge the
battery.
A
Regularly check the
electrolyte level.
A
Battery was used too
much without
recharging.
A
Charge battery
sufficiently.
A
Charge the battery properly.
Recharging is impossible.
A
Battery life expired.
A
Replace battery.
Terminals are severely
corroded and heat up.
A
Poor terminal
connection.
A
Clean the terminal
and tighten securely.
A
Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
Battery electrolyte level
drops rapidly.
A
There is a crack or pin
holes in the electrolytic
cells.
A
Replace battery.
A
Charging system
trouble.
A
Consult your local
KUBOTA Dealer.