SERVICE EVERY 500 HOURS
Perform inspection and servicing for every 50 and 250
hours of operation at the same time.
1. Checking and replenishing the oil
in the front and the rear axle case
WARNING
To avoid personal injury or death:
• Before changing the oil in the front and rear
differential axle cases, always stop the engine
and lock the shuttle-change-lever in neutral.
• Always remove the bucket and attachment, and
use the lift-arm-support-device when servicing
the machine with the loader-lift-arms raised to
avoid serious personal injury.
1. Remove the oil-port-plug, check the oil level in the
front and the rear axle case.
The oil level in the axle cases must be at the lower
rim of the thread.
Oil port plug
WOF 10 mm
2. Add the axle-cases-oil if necessary.
3. Screw in and tighten the oil-port-plug.
Front
Rear
(1) Oil port plug
Axle case oil capacity
Front
3.0 L
Rear
2. Replacing the LST oil filter
WARNING
To avoid personal injury or death:
• Never remove the filter immediately after the
engine has stopped, or hot hydraulic oil may
rush out, causing scalding.
1. Loosen the nut located the bottom of the LST-oil-
filter and remove the LST-oil-filter.
Hexagon nut
24 mm
2. Change to an new LST-oil-filter-cartridge and
reinstall the LST-oil-filter.
Hexagon nut
Tightening torque
73.6 N
⋅
m to 83.4 N
⋅
m
(7.5 kgf
⋅
m to 8.5 kgf
⋅
m)
SERVICE EVERY 500 HOURS
PERIODIC SERVICE
R430
81
Summary of Contents for R430
Page 9: ...INDEX 105 R430 5 ...
Page 10: ...6 R430 ...
Page 19: ...SAFETY LABELS SAFE OPERATION R430 15 ...
Page 20: ...SAFE OPERATION 16 R430 ...
Page 21: ...SAFE OPERATION R430 17 ...
Page 22: ...SAFE OPERATION 18 R430 ...
Page 23: ...SAFE OPERATION R430 19 ...