19
OPERATING THE ENGINE
B
Operating Procedure for Parked Regeneration
1.
Park the tractor in a safe area away from buildings, people, and animals.
2.
Apply the parking brake.
3.
Set the shuttle shift lever to the neutral position.
4.
Turn "OFF" the PTO clutch control switch.
5.
Return the engine rpm to the idle speed.
6.
Lower the implement to the ground.
7.
Press the DPF INHIBIT switch
, and the switch lamp turns "OFF".
8.
When the regeneration conditions are satisfied (2 to 5 and 7 mentioned above),
the parked regeneration switch lamp
start flashing.
9.
Press the parked regeneration switch
to start the regeneration cycle.
(The switch lamp will stop flashing and remain "ON" constantly during the cycle.)
10.
The engine rpm will automatically rise, and the regeneration process will begin.
11.
Both indicators
stay "ON" while regenerating the DPF.
They turn "OFF" when the cycle is complete.
12.
After the lamp turns "OFF", normal tractor work may resume.
When driving in "Regeneration Inhibit" mode, press the DPF INHIBIT switch to turn on the switch lamp.