PERIODIC SERVICE
C
Fan / Air-conditioner Belt Routing
B
Cleaning Water Separator
[M6-101, M6-111]
This job should not be done in the field, but in a clean
place.
1. Disconnect the connector of water sensor.
2. Close the fuel shutoff-valve.
3. Unscrew the cup and remove it, then rinse the inside
with kerosene.
4. Take out the element and dip it in the kerosene to
rinse.
5. After cleaning, reassemble the water separator,
keeping out dust and dirt.
6. Connect the connector of water sensor.
7. Bleed the fuel system.
(See "SERVICE AS REQUIRED" in "PERIODIC
SERVICE" section.)
[M6-131, M6-141]
This job should not be done in the field, but in a clean
place.
1. Disconnect the connector of water sensor.
2. Unscrew the cup and remove it, then rinse the inside
with kerosene.
3. Take out the element and replace it with a new one.
4. After cleaning, reassemble the water separator,
keeping out dust and dirt.
5. Connect the connector of water sensor.
6. Bleed the fuel system.
(See "SERVICE AS REQUIRED" in "PERIODIC
SERVICE" section.)
A
If a fuel element is broken, replace it with new one.
(1) Belt
(2) Drive pulley
(3) Air-conditioner compressor
(4) Alternator
(5) Fan pulley
(6) Self-tension pulley
(1) O ring
(2) Element
(3) Element cup
(4) Red float
(5) Cup
(6) Drain plug
(7) Water sensor connector
(1) O ring
(2) Element
(3) Water sensor connector
(4) Cup
(5) Drain plug
Summary of Contents for M6-101-M6-111
Page 6: ......
Page 14: ......
Page 22: ...SAFE OPERATION 8 7 DANGER WARNING AND CAUTION LABELS ...
Page 23: ... 9 SAFE OPERATION ...
Page 24: ...SAFE OPERATION 10 ...
Page 25: ... 11 SAFE OPERATION ...
Page 26: ...SAFE OPERATION 12 ...
Page 28: ......
Page 128: ...TIRES WHEELS AND BALLAST 100 ...