SAFE OPERATION
HANDLING ELECTRICAL COMPONENTS
Always exercise extra caution when handling electrical
equipment. Careless handling of electrical components
can cause serious personal injury, death by electrocution
or property damage.
¡
DO NOT touch the electrical system during operation.
¡
Connect or disconnect the load to the AC receptacles or
terminals only when the engine is stopped.
¡
Make certain that all power cables and wiring are in
good condition. Bare wire or frayed insulation can
cause dangerous electrical shock, burns or death.
¡
DO NOT use the generator in damp or wet conditions.
Handling terminals and cables with wet hands can
result in personal injury or death.
¡
Always shut the engine off and allow to cool before
cleaning. Use water sparingly when cleaning the
outside of the generator. Make sure that water does not
splash onto the electrical system or into the generator.
¡
DO NOT touch the generator with wet hands. You may
get an electric shock that can cause burns or death.
¡
DO NOT connect this generator to any building's
electrical system unless an isolation switch has been
installed by a licensed electrician.
¡
DO NOT run other generators in parallel.
¡
Always turn off the circuit breaker and all
switches for the electrical devices before starting
the generator.
¡
Check the wiring and connections of the electrical
devices before starting the generator.
¡
Be sure to check the engine before operation. If
something is wrong with the engine, repair it
immediately and before operation.
¡
Keep all guards and shields in place before
operating the generator. Replace any that are
damaged or missing.
¡
Check to see that bystanders are in a safe distance
from the generator before starting.
¡
Always keep the generator at least 1 m away from
buildings and other facilities.
¡
DO NOT allow children or livestock to approach
the generator while the engine is running.
¡
DO NOT start the engine by shorting across
starter terminals or bypassing normal starting
circuit. The generator may start unexpectedly
causing electric shock to others.
CHECK BEFORE OPERATION & STARTING THE ENGINE
Summary of Contents for KJ-S130VX
Page 1: ...G3601 8911 8 ...
Page 55: ...39 ENGLISH TROUBLESHOOTING 쎱 When Engine must be Stopped Immediately 쎱 When Engine Overheats ...
Page 56: ...40 ENGLISH TROUBLESHOOTING ...
Page 57: ...41 ENGLISH WIRING DIAGRAM Engine Circuit Diagram for D1703 V2203 ...
Page 58: ...42 ENGLISH WIRING DIAGRAM Engine Circuit Diagram for V3300 ...
Page 63: ...47 ENGLISH WIRING DIAGRAM Generator Circuit Diagram KJ S130VX AUS 240V 50Hz ...
Page 65: ...49 ENGLISH WIRING DIAGRAM Generator Circuit Diagram KJ S240 AUS 240V 50Hz ...
Page 66: ...50 ENGLISH WIRING DIAGRAM Generator Circuit Diagram KJ T300 AUS 415 240V 50Hz ...