Page No. 33
Kubota Emission-Related Installation Instructions
Document Number : KEA-STD-03-CRS-DOC-001-
④
Appendix 5
2-5 Intake System Flexibility Limitations
See below for installation limitations for the following engines:
V2403-CR-TIE4B-KEA-1 (1J498-10000)
V2403-CR-TIE4B-KEA-2 (1J498-20000)
If the air inlet hose is rotated 90 deg. about the turbo charger axis (option #4), the following air cleaner installation combinations
ARE
acceptable
:
A. The exact combination of AC Inlet, AC Angle, and Heights in this table can be used as specified.
B. Any other combination not listed in this table is not permitted.
2. Intake System
2-5-3. Air Intake System Flexibility Limitations
Acceptable Combinations for V2403-CR-TIE4B-KEA-1, V2403-CR-TIE4B-KEA-2
ACInlet
(Option #1)
ACAngle
(Option #3)
Height
(Option #2)
Inlet Hose Angle
(Option #4)
ACInlet
ACAngle
Inlet Hose
Angle
Height
0
90
90
Standard ( 0 mm Extension )
180
90
90
Standard ( 0 mm Extension )
180
180
90
Standard ( 0 mm Extension )
0
270
90
Standard ( 0 mm Extension )
180
90
90
Extension = 250 mm Fixed Length
0
180
90
Extension = 250 mm Fixed Length
180
90
90
Extension = 500 mm Fixed Length