background image

Page 6

www.kuebler.com

(-) BL

(+) BL

INP A

INP B

n.c.

n.c.

GND

1

2

3

4

5

6

7

8

n.c.

max. 30 V DC

24 V DC ±20 %, 50 mA

DC-Type:  

6.136.012.8x1

DC-Type: 
6.136.012.8x0

Screw terminal 1: 

Fast frequency input 

NPN:  

active for negative edge

Input resistance:  approximately 1 MOhm
Max. frequency:  7 kHz (pulse/pause: 1:1)
Low level: 

0…0,7 V DC

High level: 

3…30 V DC

PNP: 

active for positive edge

Input resistance:  approximately 100 kOhm
max. frequency:  12 kHz (pulse/pause: 1:1) 
Low level: 

0…0,7 V DC

High level: 

4…30 V DC

Screw terminal 2: 

Slow frequency input 

NPN:  

active for negative edge

Input resistance:  approximately 1 MOhm
Max. frequency:  30 Hz (pulse/pause: 1:1)
Low level: 

0…0,7 V DC

High level: 

3…30 V DC

PNP: 

active for positive edge

Input resistance:  approximately 100 kOhm
max. frequency:  30 Hz (pulse/pause: 1:1) 
Low level: 

0…0,7 V DC

High level: 

4…30 V DC

Screw terminal 3, 4 and 5:

no function

Screw terminal 6: 

Common GND connection for all inputs

Screw terminal 7: 

(–) external power supply for the backlight option

Screw terminal 8: 

(+) external power supply for the backlight option
(24 V DC ±20 %, 50 mA)

Scope of delivery:

 

Digital display 
Clamp 
Front frame for screw mounting, 
Panel cut-out 50 x 25 mm
Front frame for clamp mounting,  
Panel cut-out 50 x 25 mm
Seal
Operating instructions 

Note:

This product includes a 

lithium battery. Do 

not open it by force, do not throw it in the 
fire. Avoid temperatures below –20 °C and 
above 70 °C!

t

Connections:

Input specification and terminal assignment
Screw terminal

No 1

No 2

No 3 No 4 No 5 No 6

No 7

6.136.012.8x0
6.136.012.8x1

7 kHz

12 kHz

NPN

PNP

30 Hz

NPN
PNP

Backlighting(–)

    Designation 

Model

INP A

INP B

BL 

No. 8

BL 
+

Backlighting (+)

0 V DC

GND

Table 2

Summary of Contents for CODIX 136

Page 1: ...e itsvorkehrungen treffen 1 4 Schalttafeleinbau Montieren Sie das Gerät entfernt von Wärmequellen und vermeiden Sie direkten Kontakt mit ätzenden Flüssigkeiten heißem Dampf oder ähnlichen Achten Sie bei der Installation auf eine ausreichende Kühlung des Gerätes 1 5 Montageanleitung Befestigungsrahmen vom Gerät abziehen Gerät von vorne in den Schalttafelausschnitt einset zen und auf korrekten Sitz ...

Page 2: ...zeigeneinheit 1 s Max Frequenz bei Impuls Pausenfrequenz 1 1 12 kHz Min Frequenz 1 Hz Anzeigerefresh 1 s Messprinzip Torzeitmessprinzip 1s d h innerhalb der Messzeit von 1 s werden die ankommenden Impulse gezählt und auf die Einheit 1 s umgerechnet Genauigkeit 0 05 Gehäuse Schalttafelgehäuse 48 x 24 mm nach DIN 43 700 RAL 7021 Schalttafelausschnitt 22 2 0 3 x 45 0 6 mm Einbautiefe ca 48 mm Gewicht...

Page 3: ...samer GND Anschluss für alle Eingänge Schraubklemme 7 externe Spannung bei Option LCD Hinterleuchtung Schraubklemme 8 externe Spannung bei Option LCD Hinterleuchtung 24 V DC 20 50 mA Lieferumfang Digitalanzeige Spannbügel Frontrahmen für Schraubbefestigung Einbauquerschnitt 50 x 25 mm Frontrahmen für Spannbügelbefestigung Einbauquerschnitt 50 x 25 mm Dichtung Bedienungsanleitung Hinweis Dieses Pro...

Page 4: ...from heat sources and avoid direct contact with corrosive liquids hot steam or similar When mounting the device make sure it is sufficiently cooled 1 5 Mounting instructions Remove the mounting clip from the device Insert the device from the front into the panel cut out ensuring the front panel gasket is correctly seated Slide the fixing clip from the rear onto the housing until the spring clamps ...

Page 5: ...2016 1101 RoHS Regulations S I 2012 3032 Power supply Non replaceable lithium battery lifetime approximately 8 years at 20 C Working temperature 10 55 C Operating temperature 10 60 C Storage temperature 20 70 C Relative humidity 85 non condensing Altitude to 2000 m Backlighting must be powered by an external elecrical source 24 V 20 50 mA 1 9 Start up Is the device set and programmed correctly fun...

Page 6: ...oximately 100 kOhm max frequency 30 Hz pulse pause 1 1 Low level 0 0 7 V DC High level 4 30 V DC Screw terminal 3 4 and 5 no function Screw terminal 6 Common GND connection for all inputs Screw terminal 7 external power supply for the backlight option Screw terminal 8 external power supply for the backlight option 24 V DC 20 50 mA Scope of delivery Digital display Clamp Front frame for screw mount...

Page 7: ...stré Montez l appareil loin de toute source de chaleur et évitez tout contact direct avec des liquides corrosifs de la vapeur chaude ou des substances similaires Lors de l installation veiller à assurer un refroidissement suffisant de l appareil 1 5 Instructions de montage Retirer le cadre de fixation de l appareil Introduire l appareil par l avant dans la découpe d en castrement du panneau et vei...

Page 8: ...de functionnement 10 60 C Température de stockage 20 70 C Humidité relative 85 sans condensation Altitude jusqu à 2000 m Rétroéclairage doit être alimenté par une source électrique extérieure 24 V 20 50 mA Exécutions DC Utiliser des fils blindés pour les entrées de comptage et de commande afin d obtenir la résistance CEM maxima le ou connecter au GND 0 V les entrées de comptage non utilisées 1 9 M...

Page 9: ...ccordement GND commun à toutes les entrées Borne à vis 7 alimentation extérieure pour l option rétroéclairage Borne à vis 8 alimentation extérieure pour l option rétroéclairage 24 V 20 50 mA Etendue de la livraison Afficheur digital Etrier de montage Cadre avant pour fixation par vis Découpe d encastrement 50 x 25 mm Cadre avant pour fixation par étrier Découpe d encastrement 50 x 25 mm Joint Inst...

Page 10: ... batteries Specific provisions for returning lithium batteries Avoid short circuits For that purpose protect the poles with isolating tape The poles of the lithium battery shall not come in contact with metallic objects neither by accident nor intentionally Batteries containing pollutants are marked with a symbol representing a crossed out garbage can and the chemical symbol of the heavy metal tha...

Page 11: ...Abmessungen Dimensions Dimensions Senkung Af3 DIN 74 Countersinking Af3 DIN 74 Fraisure Af3 DIN 74 1 Schalttafelausschnitt Panel cut out Découpe d encastrement ...

Page 12: ...R60341 0009 Index 3 Kübler Group Fritz Kübler GmbH Schubertstrasse 47 D 78054 Villingen Schwenningen Germany Phone 49 7720 3903 0 Fax 49 7720 21564 info kuebler com www kuebler com ...