4
Operating instructions
Electronic totaliser and
tachometer
CODIX 525
1. Description
• 6digit adding counter and frequency meter,
resetable
• LED-Display with 8 mm high characters and
very high luminosity
• Display range 0..999999 with leading zero
blanking.
• Programming of count functions and operating
parameters via the setting keys. During
programming the display guides the user with
text prompts.
• Programmable features:
Input polarity (npn or pnp)
Max. count frequency (30 Hz or 20 kHz)
Scaling factor (totaliser)
Decimal point (totaliser)
Reset mode (totaliser):
electrical
manual
manual and electrical
no reset
Scaling factor (frequency meter)
Decimal point (frequency meter)
Display mode (frequency meter)
1/min
1/sec
Time to wait until „0“ is displayed
2. Inputs
INP
Dynamic count input. Max. count frequency 30 Hz
or 20 kHz programmable via set up
RESET
Dynamic reset input. Linked to the red reset key.
3. Setting of the parameters
3.1 Selecting the displayed value
By pressing the right key, it can be chosen
whether the current value of the totaliser or the
frequencymeter is displayed.
Pressing the right key once the current function
(„total“ or „tacho“) is displayed for 2 seconds. If
within this period the right key is pressed again,
the current function is changed. The display
shows the new function „tacho“ or „total“.
3. 2 Setting the operating parameters
a. Hold down both keys on front panel and switch
on the supply voltage.
b. The display shows
c. After releasing the keys the display alternates
between menu title and corresponding menu
item at a frequency of 0.5 Hz. After any key is
pressed, only the menu item is displayed.
d. Pressing the right key, the menu item will be
switched to next value.
e. Hold down the left key and press the right key
to switch to the next menu title.
f. After programming the last menu item, the
programming routine will be left and the new
values will be stored by switching the menu
item to „YES“. If you chose „NO“, the
programming routine will be passed through
once again.
4. Programming routine
Programmable parameters are shown in
succession. After one pass, the device is fully
programmed.
In each case the first shown item is the factory
preset.
- Subject to change without prior notice -