14
5.3.8 Shape of output 1
(only if preset 1 is activated)
Permanent signal.
Is activated at count
value
³
preset 1.
Permanent signal.
Will become passive
at count value
³
preset 1.
Timed signal.
Will become passive at
count value
³
preset 1.
Timed signal.
Is activated at count value
³
preset 1.
5.3.9 Duration of the timed signal of output 1
(only if a
timed signal has been programmed in 5.3.8)
The duration can be set between 0.01 sec.
and 99.99 sec.
A 0.00 setting is not accepted
5.3.11 Duration of the timed signal of output 2
(only if
a transient signal has been programmed in 5.3.10)
The duration can be set between 0,01 sec.
and 99,99 sec.
A 0.00 setting is not accepted
5.3.12 End of programming
Programming is carried out once more.
The values input can be checked and
modified.
Programming is complete and the values
input are taken over as new parameters.
Then the device is ready for operation.
5.3.10 Shape of output signal 2
Permanent signal.
Is activated at count
value
³
preset 2.
Permanent signal.
Will become passive
at count value
³
preset 2.
Timed signal.
Will become passive at
count value
³
preset 2.
Timed signal.
Is activated at count value
³
preset 2.
5.3.7 Preset 1
Preset 1 activated
Preset 1 disactivated and without function
5.3.6 Maximum pulse waiting time
This value indicates the time during which the device will wait for a
pulse before displaying a 0 speed.
Maximum delay 01.1 sec. (minimum
value)
Maximum delay 99.9 sec.
Values below 1.1 sec. are ignored and set automatically to 1.1 sec.
5.3.5 Display mode
Conversion and display of the frequency /
speed in 1/sec.
Conversion and display of the frequency /
speed in 1/min.
6. Setting of the presets
If a push-button with an arrow or the ”
P
” push-button is
pressed, the device jumps from the display of the
counter to the display of the preset 1. A second
operation of push-button ”
P
” switches to the preset 2.
About 4 seconds after the last operation of a push-
button the device jumps back to the display of the
counter and takes over a new preset value.
Exception: in the time counter mode, the new value is
taken over immediately.
Once the preset is displayed, the “
ç
” push-button
allows to choose the decade to be modified. This
decade then blinks at a 1 Hz frequency. The “
é
” push-
button allows you to raise the value of the decade. On
the most significant decade, after the value ”
9
”, the
sign ”
-
” is displayed. The following operation of the “
é
”
push-button displays ”
-1
” again. A new operation of the
“
é
” push-button lets the display of this decade start
again at ”
0
”.
Caution:
in case of automatic repetition, preset 2
cannot be given negative values.