Kubic CA15 Manual Download Page 2

DE

DE

EN

EN

DE

DE

EN

EN

1. CONTROL UNIT CA15

1.1. General

Control unit CA15 is intended for the control of 1-

phase sauna heaters (–8 kW) in family saunas which 

do not have fixed control devices (1-phase electrical 

system).

Before you switch the heater on check always that 

there aren’t any things over the heater or in the near 

distance of the heater.

The control unit CA15 can be used to control the 

electric heaters of both family saunas and communal 

saunas up to 15 kW.

With control unit it is possible to select the maximum 

length of time the heater is to be kept on (4, 6, or 1 

hours) by means of the DIP switches situated within the 

unit (to be carried out by an electrician). The factory 

setting is 4 hours. See 3.4. Note! For family saunas 

the maximum setting time is 4h or 6h. The maximum 

setting of 1 h applies to communal saunas.

The  components  of  the  sensor  box  monitor  the 

functioning  of  the  control  unit.  The  temperature 

sensor  and  the  overheating  limiter  are  located  in 

the sensor box. The temperature is sensed by an NTC 

thermistor, and there is an overheating limiter that 

can be reset. In case of malfunction, this overheating 

limiter will cut off the heater power permanently (the 

overheating limiter can be reset by pressing the reset 

button, see Figure 1). Mechanical damage (power 

failure/short circuit) will cause an error message (Er1, 

Er, or Er3) to appear in the display of the control unit 

and the heater power will be cut off.

• 

Er1=temperature measuring circuit cut off

• 

Er=temperature measuring in short circuit

• 

Er3=overheating limiter circuit cut off

The error message will disappear after the malfunc-

tion has been corrected.

1. STEUERGERÄT CA15

1.1. Allgemeines

Das CA15-Steuergerät ist für die Steuerung einphasiger 

elektrischer Öfen (–8 kW) in Familiensaunen gedacht, 

die  keine  eigebauten  Regler  haben  (einphasige 

Elektrosystem).

Bevor Sie den Ofen anschalten, bitte überprüfen, 

dass keine Gegenstände auf dem Ofen oder in der 

unmittelbarer Nähe des Ofens liegen.

Mit dem Steuergerät CA15 können Elektrosaunöfen 

bis 15 kW sowohl für Familiensaunen als auch für 

allgemeine Saunen bedient werden.

Bei dem Steuergerät ist es möglich, die maximale 

Einschaltdauer des Ofens mit Hilfe der DIP-Schalter 

im Innern des Gerätes (der Installateur nimmt die 

Einstellung vor) auf 4, 6 oder 1 Stunden einzustellen. 

Die werkseitige Einstellung ist 4 h. Vgl. Abschnitt 3.4. 

Achtung! In Familiensaunen ist die maximale Ein-

schaltzeit entweder 4h oder 6h und in öffentlichen 

Saunen 1h.

Die Funktionen des Steuergeräts werden von den 

Komponenten des Fühlergehäuses gesteuert/geregelt. In 

dem Fühlergehäuse befinden sich ein Temperaturfühler 

und ein Überhitzungsschutz. Ein NTC-Thermistor tastet die 

Temperatur ab, und der rückstellbare Überhitzungsschutz 

unterbricht beim Auftreten eines Defekts die Stromzufuhr 

zum Saunaofen (der Überhitzungsschutz kann durch 

Drücken der entsprechenden Taste zurückgestellt werden, 

siehe Abb. 1).  Mechanische Schäden an den Stromkreisen 

der Temperaturfühler und der Überhitzungssicherung 

(Unterbrechung/Kurzschluss) bewirken Störungsanzeige 

am Display des Steuergeräts (Er1, Er oder Er3) und 

Stromunterbrechung des Ofens.

 

Er1=Unterbrechung im Temperaturfühlerkreis

 

Er=Kurzschluss im Temperaturfühlerkreis

 

Er3=Unterbrechung im Stromkreis des 

 

Überhitzungsschutzes

Die  Störungsanzeige  verschwindet,  sobald  der 

Fehler behoben ist.

CONTENTS

1.   CONTROL UNIT CA15 .....................................
 

1.1.  General ....................................................

 

1..  Technical data .........................................3

.   INSTRUCTION FOR USE OF 
 

CONTROL UNIT ...............................................3

3.   INSTRUCTIONS FOR INSTALLING 
 

THE CONTROL UNIT ........................................5

 

3.1.  Removing the top plate ..........................5

 

3..  Fastening the device to the wall ............5

 

3.3. Installation of Sensor Box .......................5

 

3.4.  Changing the pre-set time  .....................6

 

3.5.  Service instructions for the 

 

 

control unit .............................................6

INHALT

1.   STEUERGERÄT CA15 .......................................
 

1.1.  Allgemeines ............................................

 

1..  Technische Daten ....................................3

.   ANLEITUNG FÜR DEN BENUTZER DES 
 

STEUERGERÄTS ..............................................3

3.   ANLEITUNG FÜR DEN INSTALLATEUR 
 

DES STEUERGERÄTS .......................................5

 

3.1.  Lösen des Deckels ...................................5

 

3..  Wandbefestigung  ..................................5

 

3.3.  Installation des Fühlerkastens ...............5

 

3.4.  Änderung der Einschaltzeit ....................6

 

3.5.  Wartungsanleitung für das

 

 

Steuergerät .............................................6

EN

DE

Summary of Contents for CA15

Page 1: ...CA15 Control unit Steuergerät EN DE ...

Page 2: ...m Ofen oder in der unmittelbarer Nähe des Ofens liegen MitdemSteuergerätCA15 können Elektrosaunöfen bis 15 kW sowohl für Familien saunen als auch für allgemeine Saunen bedient werden Bei dem Steuergerät ist es möglich die maximale Einschaltdauer des Ofens mit Hilfe der DIP Schalter im Innern des Gerätes der Installateur nimmt die Einstellungvor auf4 6oder12Stundeneinzustellen Die werkseitige Einst...

Page 3: ...mbersandtheindicatorlight 5 will flash The maximum temperature that can be set is 110 C 5 Signal light red When the signal light is on continuously the display shows the temperature of the sauna 1 2 Technische Daten die maximale Temperatureinstellung am Display desSteuergerätsbeträgt110 C Präzision 1 C die maximale Temperaturanzeige ist 125 C Maße des Steuergeräts Breite 250 mm Höhe 223 mm Tiefe c...

Page 4: ...sed Thepersoninchargeoftheinstallationofthecontrol unitshoulddelivertheinstructionsforinstallationand for use with the heater and give the necessary user training for the person attending the heater and the control unit before installation is completed Bei Blinken der Leuchte zeigt das Display die Einstellungstemperatur an 6 Kontrolleuchte grün Gibt an dass auf der Anzeige die Vorwahlzeit angegebe...

Page 5: ...as Steuergerät wird außerhalb der Saunakabine an einem trockenen Ort Betriebstemperatur 0 C Achtung Das Steuergerät darf nicht in die Wand konstruktion versenkt werden Siehe Abb 2 3 1 Lösen des Deckels Der Deckel wird vor der Installation des Steuergeräts an der Wand abgenommen Der Deckel wird am oberenRandgelöst wenndiedenDeckelblockierende Laschez B miteinemSchraubenzieherherabgedrückt wird Am u...

Page 6: ...with heaters attached to the floor Abbildung 6 Lage des Fühlergehäuses des Steuergeräts CA15 bei Saunaofen Standmodellen Figure 7 DIP switches Please note 12 hours only for communal use 4 and 6 hours for family and communal use Abbildung 7 DIP Schalter Achtung 12 h nur für gewerbliche und Vereinssaunen 4 h und 6 h für die Nutzung durch Familien und gewerbliche bzw Vereinssaunen 3 4 Changing the pr...

Page 7: ...derstand des Heißleiters beträgt 22kΩ kilo ohm bei einer Temperatur von 25o C Figure 8 Abbildung 8 Figure 9 Abbildung 9 The electric power card must be changed if indicator light 8 shows the heater is on but it is not starting to heat up contactors relays are not connected contactors relays are in the on position but the heater does not come on Blown fuses fig 10 if the indicator lights on the dis...

Page 8: ...45E 4 5 5 x 1 5 3 x 10 5 x 1 5 4 x 0 25 3 x 1 5 KKIP60E 6 0 5 x 1 5 3 x 10 5 x 1 5 4 x 0 25 3 x 1 5 KKIP80E 8 0 5 x 2 5 3 x 16 5 x 2 5 4 x 0 25 3 x 1 5 KK10 5 10 5 5 x 2 5 3 x 16 5 x 2 5 4 x 0 25 3 x 1 5 KK15 15 0 5 x 6 0 3 x 25 5 x 6 0 4 x 0 25 3 x 1 5 For unit Zum Steuergerät Fuses Sicherungen For heater Zum Ofen HO7RN F For thermostat Zur Thermostat For Light Added control system Zur Licht Zusa...

Reviews: