4.1 Back
1.
Socket for coils:
The connecting socket for coils is located on the left side. The
connector plug of the searchcoil has to be plugged into the socket. Before removing the
plug the locking knob must be pressed, only then an extraction is possible. The connector
is compatible with all GOLD ID-XL searchcoils.
2.
Headphone socket:
Any commercial headphones with 6.3 mm jack can be plugged in.
During use the loudspeaker is turned off. Matching, light weight headphones are provided.
3.
Charger
(connection to the charging device): To recharge the battery, insert the plug of
the charger into the provided socket and check the charging process. The maximum
charging time is 90 minutes (to avoid a defect on the charger or the built-in battery, please
do not exceed this time). The charger connector should be removed after each charge.
The GOLD ID-XL is ready for use within a very short time:
1.
Activate the metal detector with the ON-/OFF-button. The respective searchcoil should be cable-
connected to the electronic unit beforehand.
2.
Hold the searchcoil towards the ground and press the Reset-button for a brief moment. You
herewith attain a zero balance, which is necessary for a trouble-free search. Please make sure,
that there are no metal objects near the searchcoil during zero balance. This could cause a wrong
adjustment of the metal detector and produce unwanted indicator effects (as the case may be
repeat the Reset
-
procedure on another, metal-free spot).
3.
Please set the frequency initially to the lowest level (turn the Freq.-modulator counterclockwise).
By means of Audio control the volume is set. To become acquainted with the handling of the
device we generally recommend to start with the lowest frequency adjustment. With progressing
experience it is expedient, to increase the frequency gradually what will have a positive effect on
the search performance.